- 9 -

Once the HP is connected to the water circuit with the bypass, and is connected to the power supply by a professional, ensure that:

The HP is horizontal (level).

The HP is secured and stable.

The water circuit has been purged of air that has been trapped in the piping of the HP.

The pressure gauge, at the back of the HP, shows a temperature that is equal to the ambient outdoor temperature.

The water circuit is properly connected (no leaks or damage to the hydraulic connections, the connections are properly tightened).

The electric circuit is properly connected (the cables are tightly secured to the terminals and intermediate circuit-breaker), properly insulated, and con-
nected to the earthing connection.

The conditions of installation and use described above have all been met.

The outdoor temperature is between 0 and +35°C.

The water temperature is of 15°C minimum.

The evaporator at the rear/on the sides of the HP is clean (leaves, dust, pollen, cobwebs...)

You can now start your device by following, in the given order, the following steps:

Open the 3 valves of the bypass (refer to the hydraulic diagram).

Half-close the bypass valve.

Remove all unused items or tools from the area surrounding the HP.

Start the pump of the filtration system.

Power up the HP by engaging the circuit-breaker and using the ON/OFF button of the display.

Check that the HP starts and stops in sync with the filtration circuit: if no water is detected in the HP, the display shows “FLO”

The HP starts after a delay of a few minutes.

Adjust the temperature (“Regulation” chapter).

Adjust the water flow (“Water flow setting” chapter).

After a few minutes, you can adjust the bypass valve as indicated in the “Water flow setting” chapter. Having completed the above steps, cover the pool and
let the HP operate for a few days with the filtration pump in “forced mode” until the water of the pool reaches the desired bathing temperature.

USE

Cover the pool with a cover (bubble cover, shutter...) to reduce heat losses.

IMMERSION AND  STARTING OF HP

Heating priority (Option):

The filtration pump can be connected to the HP to force the filtration to operate if the water is not at the desired temperature.
Prior to this connection, a “dry contact” (normally open relay or connector) with a 230V AC coil should be provided.

Electrical connections:

Connect the coil of this relay (A1 and A2) on the P1 and P2 terminals of the HP.

Connect the input and the output of the dry contact (normally open) in parallel with the dry contact of the filtration clock of the swimming pool.

Parameter for taking the connection into account:

 Check that 

the setting of the filtration pump parameter (parameter #9) is 
set to “2”. If this is not the case, please contact us to change the 

setting.

Содержание PEARL HPF09

Страница 1: ...HEAT PUMPS PEARL INVERTER T H E I N T E L L I G E N T S W I M M I N G P O O L H E A T P U M P OFFICIAL PRODUCT HANDBOOK effortless heating solutions BWTROBOTS CO NZ ...

Страница 2: ...Instructions Manual BWT PEARL HPF 9 BWT PEARL HPF 13 BWT PEARL HPF 16 BWT PEARL HPF 20 BWT PEARL HPF 24 BWT PEARL HPF 28 EN ...

Страница 3: ... electronic appliances are recycled information available from your local waste treatment service This product contains potentially hazardous substanc es DELIVERY AND TRANSPORT When you have unpacked the HP please check the content to report any damage Please also check that the pressure reading on the pressure gauge corre sponds to the outside temperature as different values might indicate a leak...

Страница 4: ... 11 5 4 2 Kw 14 8 4 9 kW 18 2 6 8 kW 22 8 8 1 kW COP ECO Mode 6 7 5 6 7 0 4 7 6 7 4 4 6 6 4 5 6 7 4 4 6 5 4 2 Capacity in SILENT 3 8 3 2 kW 3 7 kW 4 2 kW 4 9 kW 6 8 kW 8 1kW COP SILENT 6 7 5 6 7 6 7 6 6 6 7 6 5 Noise level mini maxi at 10m according to EN ISO 3744 2010 21 25 dB a 23 28 dB a 25 30 dB a 25 30 dB a 26 31 dB a 26 32 dB a Operating temperature 15 C 38 C Compresseor type 2D Technology F...

Страница 5: ... connection P 20 Immersion and starting of HP P 22 Use P 22 Settings P 23 General use P 23 Regulation Electronic controller P 24 Mobile application BWT Inverter P 25 Controller state table P 26 Maintenance P 27 Wintering P 27 Recycling the HP P 28 After sales technical Departement P 28 CONTENTS ...

Страница 6: ...s and severe injuries and even death Do not touch the fan or the moving parts and do not insert objects or your fingers close to the moving parts when the device is operating Moving parts can cause severe injuries and even death Do not pull on the hoses and the connections to move the machine WARNINGS CONCERNING ELECTRICAL APPLIANCES The power supply of the device must be protected by a 30 mA secu...

Страница 7: ... et fixe en plaçant les patins fournis sous les pieds Pour le béton utiliser des tire fonds adaptés de ø8 mm équipés de rondelles pour empêcher tout desserement Pour le bois utiliser des vis adaptées de ø8 mm à tête hexagonale équipées de rondelles frein pour empêcher tout desserement Espace à préserver autour de la PAC INSTALLATION SITE TYPE DE SUPPORT ESPACE À PRÉVOIR Dimensions minimales de la ...

Страница 8: ...ction order of the phases If phases are inverted the compressor of the HP will not work In public spaces the installation of an emergency stop button close to the HP is mandatory The voltage must match the voltage mentioned on the HP The connections must be sized based on the power of the HP and on the installation state By pass Provided connections ø 50mm Evacuation of the condensate Water treatm...

Страница 9: ...force The electric cables must be buried at a depth of 50 cm 85 cm under a road or a path in an electrical sheath red corrugated When a cable buried in a sheath crosses another cable or a pipe gas water etc the distance between them must be greater than 20 cm Automation You have a very low voltage terminal block to which you can connect your home automation This is an ON OFF dry contact Remove the...

Страница 10: ...P by engaging the circuit breaker and using the ON OFF button of the display Check that the HP starts and stops in sync with the filtration circuit if no water is detected in the HP the display shows FLO The HP starts after a delay of a few minutes Adjust the temperature Regulation chapter Adjust the water flow Water flow setting chapter After a few minutes you can adjust the bypass valve as indic...

Страница 11: ...ange When stopped the temperature reading should be close to the temperature of the swimming pool water If the hand shows 0 the device should not be used contact your distributor Setting frequency The flow through the HP depends much on water temperature and to a lesser extent on air temperature It should therefore be adjusted When the pump is started and the water is cold During the rise of tempe...

Страница 12: ...REGULATION ELECTRONIC CONTROLLER ...

Страница 13: ...e easily with our after sales technicians to solve remotly and quicly some of the machine disfuncions The module position in the HP The module is located on the side of the machine with the electrical connection blocks Download the App On apple or android store download the app thanks to the Qr code located behind the electrical supply ac cess hatch or below the nameplate of the machine Behind the...

Страница 14: ...or Check electrical connection between controller and electronic card inside the machine AL3 Probe error Water in Check probe connection AL4 Probe error Water out AL5 Probe error coil AL1 Probe error comp out AL2 Probe error comp in AL6 Probe error ambiance AL9 Fan error Check fan connection AL14 Outdoor temperature too low Outdoor temp is below 15 C Wait for the outdoor tempera ture to increase A...

Страница 15: ... pressure when heat pump is stopped manometer must indicate a pressure higher than 0 5 Please check the following points yearly Check settings Check securities Check all electrical connections and ground Check condenser cleanliness Use soft soap and water to clean the heat pump casing do not use solvents WINTERING 1 Turn off the power supply to the HP 2 Fully open the bypass valve and close the HP...

Страница 16: ... not Position of the by pass valves Contact your dealer and pass on this information together with the dimensions of the swimming pool your personal details address telephone number and the description of the failure If this procedure is respected the BWT technician will be able to make as accurate diagnostic of the failure The recommended solution made by BWT will be implemented briefly after tha...

Страница 17: ...Instructions Manual EN BWT PEARL HPT 09 BWT PEARL HPT 15 BWT PEARL HPT 20 ...

Страница 18: ...res on the main parts constituting the product indicates that it must not be discarded alongside household waste It must be brought to an adequate collection point where electronic appliances are recycled information available from your local waste treatment service This product contains potentially hazardous substanc es DELIVERY AND TRANSPORT When you have unpacked the HP please check the content...

Страница 19: ... 5 0 kW 14 5 7 0 Kw COP ECO Mode 6 6 4 7 7 7 4 7 7 9 4 5 Capacity in SILENT 3 5 kW 5 0 kW 7 0 kW COP SILENT 6 4 6 5 6 6 Noise level mini maxi at 10m according to EN ISO 3744 2010 19 28 dB a 21 30 dB a 23 32 dB a Operating temperature 10 C 38 C Compresseor type 2D Technology Full DC Expansion valve Electronic Heat Exchanger Optimal Twist Casing ABS treated against UV Refrigerant R32 Installation Wa...

Страница 20: ...l connection P 20 Immersion and starting of HP P 22 Use P 22 Settings P 23 General use P 23 Regulation Electronic controller P 24 Mobile application BWT Inverter P 25 Controller state table P 26 Maintenance P 27 Wintering P 27 Recycling the HP P 28 After sales technical Department P 28 CONTENTS ...

Страница 21: ...s and severe injuries and even death Do not touch the fan or the moving parts and do not insert objects or your fingers close to the moving parts when the device is operating Moving parts can cause severe injuries and even death Do not pull on the hoses and the connections to move the machine WARNINGS CONCERNING ELECTRICAL APPLIANCES The power supply of the device must be protected by a 30 mA secu...

Страница 22: ...ur close to equipment operating at high frequencies in a place where snow is likely to accumulate in a place where it could be flooded by the condensates produced by the device as it operates on a surface that could transfer the vibrations to the house Advice dampen the possible noise nuisance caused by your HP Do not install it close to or underneath a window Do not direct the outlet of the fan t...

Страница 23: ...ction order of the phases If phases are inverted the compressor of the HP will not work In public spaces the installation of an emergency stop button close to the HP is mandatory The voltage must match the voltage mentioned on the HP The connections must be sized based on the power of the HP and on the installation state By pass Provided connections ø 50mm Evacuation of the condensate Water treatm...

Страница 24: ...egislation in force The electric cables must be buried at a depth of 50 cm 85 cm under a road or a path in an electrical sheath red corrugated When a cable buried in a sheath crosses another cable or a pipe gas water etc the distance between them must be greater than 20 cm Automation You have a very low voltage terminal block to which you can connect your home automation This is an ON OFF dry cont...

Страница 25: ...P by engaging the circuit breaker and using the ON OFF button of the display Check that the HP starts and stops in sync with the filtration circuit if no water is detected in the HP the display shows FLO The HP starts after a delay of a few minutes Adjust the temperature Regulation chapter Adjust the water flow Water flow setting chapter After a few minutes you can adjust the bypass valve as indic...

Страница 26: ...ange When stopped the temperature reading should be close to the temperature of the swimming pool water If the hand shows 0 the device should not be used contact your distributor Setting frequency The flow through the HP depends much on water temperature and to a lesser extent on air temperature It should therefore be adjusted When the pump is started and the water is cold During the rise of tempe...

Страница 27: ... 11 REGULATION ELECTRONIC CONTROLLER ...

Страница 28: ...e easily with our after sales technicians to solve remotly and quicly some of the machine disfuncions The module position in the HP The module is located on the side of the machine with the electrical connection blocks Download the App On apple or android store download the app thanks to the Qr code located behind the electrical supply ac cess hatch or below the nameplate of the machine Behind the...

Страница 29: ...or Check electrical connection between controller and electronic card inside the machine AL3 Probe error Water in Check probe connection AL4 Probe error Water out AL5 Probe error coil AL1 Probe error comp out AL2 Probe error comp in AL6 Probe error ambiance AL9 Fan error Check fan connection AL14 Outdoor temperature too low Outdoor temp is below 15 C Wait for the outdoor tempera ture to increase A...

Страница 30: ... pressure when heat pump is stopped manometer must indicate a pressure higher than 0 5 Please check the following points yearly Check settings Check securities Check all electrical connections and ground Check condenser cleanliness Use soft soap and water to clean the heat pump casing do not use solvents WINTERING 1 Turn off the power supply to the HP 2 Fully open the bypass valve and close the HP...

Страница 31: ... not Position of the by pass valves Contact your dealer and pass on this information together with the dimensions of the swimming pool your personal details address telephone number and the description of the failure If this procedure is respected the BWT technician will be able to make as accurate diagnostic of the failure The recommended solution made by BWT will be implemented briefly after tha...

Отзывы: