HBP-V40 consisting of:
1 Top section in brass
2 Connection fitting with seals
3 Transparent cylinder with filter element
4 Hose connection for flushing water supply
5 Turning knob for the backwashing element
Observe the local installation regulations, general
guidelines, general hygiene regulations and the
technical specifications.
A connection to the sewage system (discharge) of
min. DN 40 should be available.
Attention: The installation site must be protected
against frost and must ensure the protection of the
filter against e.g. solvent vapours, fuel oil, lees,
chemicals of any kind, UV radiation and heat
sources above 40 °C.
Attention: keep the plastic parts free from grease,
solvents and acidic as well as basic detergents.
The plastic parts must be replaced even if there is
no visible damage after severe concussions and
shocks e.g. due to the use of unsuitable tools or if
dropped on stone floors etc (danger of bursting).
Avoid extreme pressure impact.
This filter is intended for the filtration of drinking
and service water. It protects the water pipes and
the connected water system parts from malfunc-
tions and corrosion damage due to impurities such
as rust particles, chippings, sand, hemp, etc. The
filter cannot be used in applications with chemi-
cally treated circulating water, process water and
cooling water for continuous cooling systems.
In applications with water containing coarse im-
purities, a coarse dirt separator must be used. The
filter is not suitable for oils, greases, solvents,
soaps and other lubricating media nor for the
separation of watersoluble substances.
The untreated water flows through the untreated
water inlet into the filter and from there from the
inside to the outside through the filter element into
the clean water outlet. Any impurities >90 μm are
trapped on the inside of the filter cloth. The filter
element needs to be cleaned by backwashing at
regular intervals. For the backwashing process,
the waste water connection is opened by turning
the turning knob and the backwashing element is
also turned. The particles on the filter cloth are re-
moved by suction and then washed out.
Scope of Supply
Application
Function
Install filter according to its nominal width in cold
water pipes of the same dimensions and before
the equipment to be protected. Install stop valves
before and after the filter.
Assemble the connection fittings (2) in the pipe
and install filter in flow direction (see flow direc-
tion arrow) in the horizontal cold water pipe (see
installation sketch).
Route the flushing water connection with hose to
the sewage channel or provide a collection basin
(capacity approx. 10 l).
Please note: According to DIN EN 1717, the
flushing water hose must be installed at a mini-
mum distance of 20mm to the highest possible
waste water level (free discharge).
Installation
Installation Conditions
Содержание Haier HBP-V40
Страница 1: ...HB Filter V40 HBP V40 Haier HBP V40 POE Filter...
Страница 2: ......
Страница 3: ...2 2 2 2 2 3 3 3 3 4 5 6 7...
Страница 4: ...1...
Страница 5: ...HBP V40 1 2 3 2 DN40 40 4 5 2 10 EN 1717 20 90...
Страница 6: ...3 3 5 5 1988...
Страница 8: ...5 35...
Страница 9: ...6...
Страница 10: ......
Страница 11: ...7 2 9 00 17 00 400 699 9999 1 2 3 1 2 1 2 3 5...
Страница 12: ......
Страница 14: ...1...
Страница 20: ......
Страница 22: ......
Страница 23: ......
Страница 24: ...CERTIFICATE OF INSPECTION Add 172 217 Tel 400 699 9999...