6
●Flush out any dirt particles by opening the handwheel
on the multi-block module.
●Connect a corrugated hose to the multiblock module
outlet and the hard water inlet (9). Be sure to observe
the arrows indicating the direction of flow.
●Connect a corrugated hose to the multiblock module
inlet and form a watertight seal with the filtered water
outlet (8).
●Route the flushing water hose at an incline to the
sewage system connection (drain) and secure the end
with the supplied fixing material to prevent it flapping
about when under pressure.
●The flushing water hose must be connected to the
channel with a distance of at least 20 mm from the
highest waste water level (unimpeded drainage).
Checklist
You can use this list to check your work again after
you have installed and started the unit.
Is there a protective filter upstream from the unit in
the immediate vicinity?
Is the water and power supply to the unit continuous
(network pressure of at least 2 bar)?
Is the Multiblock opened to the limit stop?
Have the connection hoses been properly
connected? (Observe flow direction arrows, drinking
water inlet at the non-return valve of the unit)
Has the flushing water hose been routed separately
to the sewage system and connected in compliance
with local standards? (See Installation)
Operating the controller
Factory settings
Keypad
Function of keys
Operating display
Start-up
2 14 : 49
4448 L
Display alternates between
showing the day of the week and
the time of day and the remaining
capacity in litres.
In Programming mode, the
following items flash:
Operating
range Auto
every 96 h, if remaining
capacity not 0
tP1 = 1-2 residential units
HBCF-S2002
HBCF-S3002
1800 litres
2400 litres
Confirms entries
Moves the cursor, modifies
input values
Moves the cursor
The Turn page button toggles
between the Operating and
Selection displays
1 = Monday
2 = Tuesday
3 = Wednesday
backwashing
The maximum capacity depends on polluting load
(turbidity) of the raw water. In case of a high raw water
pollution the capacity is to decrease. In case of a low
raw water pollution the capacity can be increased, for
example up to 2400 / 3000 litres.