background image

11

GB

Fault

Cause

Solution

Water pressure in systems has 

dropped considerably; Water 

pressure drops considerab-

ly when water is bled (by 

more than 35% of the static 

pressure)

Dirty filter element

Carry out backwash

Flushing water outlet cannot 

be closed

Backwash element does not 

reach final position due to 

coase dirt particles

Fully open and close turning knob; 

repeat backwash several time

13. Trouble-shooting

If the fault cannot be rectified using these notes, please contact a specialist firm or our Customer Service.

2989_EBA Diago AHA 332363-3.indd   11

13.07.11   09:57

Содержание Diago

Страница 1: ...s close at hand to avoid any mistakes and before carrying out any work on the device you should read the fitting and operating instructions carefully and follow them While our data sheets and brochures should provide advice to the best of our knowledge the content thereof is not legally binding In addition to this our general terms and conditions of trade apply Änderungen vorbehalten Subject to al...

Страница 2: ... Betriebsdruck min max bar 2 5 während der Rückspülung 16 Wassertemperatur C 30 Umgebungstemperatur C 40 Baulänge ohne Verschraubung A mm 120 120 130 Baulänge mit Verschraubung B mm 205 205 226 Gesamthöhe C mm 335 Mindesteinbaumass Rohrmitte bis Boden D mm 320 Betriebsgewicht ca kg 2 0 2 0 2 3 Batterie AA 2 Stk 1 5 V 1 Technische Daten Fig 1 Fig 2 Fig 3 Fig 3 6 1 2 5 4 Rohwasser Eintritt Rohwasser...

Страница 3: ...erden zuerst die Grobschmutz teilchen ausgespült und dann die am Filtergewebe haftenden Teilchen abgesaugt und ausgespült 5 Einbauvorbedingungen Örtliche Installationsvorschriften allgemeine Richtli nien z B WVU DIN DVGW bzw ÖVGW oder SVGW und technische Daten beachten Ein Ka nalanschluss Abfluss mind DN 40 sollte vorhan den sein Filter gemäß der Nennweite in gleichdimensionierte Kaltwasserleitung...

Страница 4: ...spar Modus Rückmeldung 4 x BEEP und 4 x BLINK 8 Bedienung Eine Rückspülung muss 1 x pro Monat durchgeführt werden um ein Festsetzen der Fremdpartikel auf dem Filtergewebe zu vermeiden bei starker Ver schmutzung eventuell öfter Vor dem Rückspülen ein Auffanggefäß unterstellen wenn der Spülwasseranschluss nicht mit dem Ka nalanschluss verbunden ist Rückspülen Drehgriff 5 gegen den Uhrzeigersinn öffn...

Страница 5: ...tion und Gewährleistung ist die Rückspülung des Filters und die Sichtkontrolle auf Dichtheit durch den Betreiber Nach DIN 1988 Teil 8 Anhang B muss der Filter re gelmäßig je nach Betriebsbedingungen spätestens jedoch alle 2 Monate rückgespült werden Eine weitere Voraussetzung für Funktion und Ge währleistung ist der Austausch der Verschleißteile in den vorgeschriebenen Wartungsintervallen Austausc...

Страница 6: ...ritt lässt sich nicht schließen Rückspülelement kommt durch Grobschmutz nicht in die Endlage Rückspülung mehrmals wiederholen 13 Störungsbeseitigung Wenn die Störung mit Hilfe dieser Hinweise nicht beseitigt werden kann so muss eine Fachfirma oder unser Kundendienst angefordert werden 2989_EBA Diago AHA 332363 3 indd 6 13 07 11 09 57 ...

Страница 7: ...Operation pressure min max bar 2 5 during back wash 16 Water temperature C 30 Ambient temperature max C 40 Length without fittings A mm 120 120 130 Length with fittings B mm 205 205 226 Total height C mm 335 Minimum distance pipe centre to floor D mm 320 Operating weight approx kg 2 0 2 0 2 3 Battery Type AA 2 pcs 1 5 V Fig 1 Fig 2 1 Technical Data Fig 3 Fig 3 6 1 2 5 4 raw water clean water 6 298...

Страница 8: ...te water connection is opened by turning the turning knob and the back washing element is also turned The particles on the filter cloth are removed by suction and then washed out 5 Installation conditions Observe the local installation regulations general guidelines general hygiene regulations and the technical specifications A connection to the sewage system discharge of min DN 40 should be avail...

Страница 9: ...nstration mode Release operation button after 3 BEEP signals and confirm with double clicks demonstration mode Response 3 x BEEP and 3 x FLASH Energy saving mode Release operation button after 4 BEEP signals and confirm with double clicks energy saving mode Response 4 x BEEP and 4 x FLASH 8 Operation A backwash must be carried out once a month to prevent dirt particles from settling on the filter ...

Страница 10: ...ations or rating plate Any warranty work may only be carried out by our Customer Service Warranty work to be carried out by an external specialist firm requires the express consent of our Customer Service Manager 11 Operator responsibility You bought a high quality product with a long life time To assure the function every technical equip ment needs to be serviced Regular back washing and checks o...

Страница 11: ...r element Carry out backwash Flushing water outlet cannot be closed Backwash element does not reach final position due to coase dirt particles Fully open and close turning knob repeat backwash several time 13 Trouble shooting If the fault cannot be rectified using these notes please contact a specialist firm or our Customer Service 2989_EBA Diago AHA 332363 3 indd 11 13 07 11 09 57 ...

Страница 12: ...wt be BWT Pharma Biotech AG CH 4147 Aesch Hauptstraße 192 Phone 41 61 755 88 99 Fax 41 61 755 88 90 E Mail info christ aqua ch BWT Česká republika s r o CZ 251 01 Říčany Lipová 196 Čestlice Phone 420 272 680 300 Fax 420 272 680 299 E Mail info bwt cz BWT Hungária Kft H 2041 Budaörs Budapark Keleti u 7 Phone 36 23 430 480 Fax 36 23 430 482 E Mail info bwt hu HOH Water Technology A S DK 2670 Greve G...

Отзывы: