7.2 Error rectification
App screen
Flashing LEDs
Cause
Remedy
vacuum
permeate
OFF
ON
OFF
ON
Status LED turns red
and a warning signal
sounds.
Pressure sensor for
permeate is defective.
Disconnect device
from electricity and
water supply.
Inform service staff.
leakage
OFF
ON
OFF
ON
Status LED turns red
and a permanent warn-
ing signal sounds.
Leak or condensation
inside the device.
Disconnect device
from electricity and
water supply.
Inform service staff.
fault
inlet h2o
meter
OFF
ON
OFF
ON
x3
x3
The status LED
repeatedly flashes
three times.
INLET WATER
fault
liter
OUTLET WATER
09852
liter
OUTLET PRESS
0.6
bar
1033
hours
OUTLET FLOW
090
liter/hour
DAYS
186
back
info
PUMP PRESS
0.6
bar
123
18.3
C°
COND TEMP
uS
The inlet water meter
is blocked or has no
power supply.
Permeate is still pro-
duced but the inlet
water volume is not
recorded.
Check power supply.
Inform service staff.
pump
pressure
OFF
ON
OFF
ON
x4
x4
The status LED repeat-
edly flashes four times.
Pump pressure is too
high.
Check the flow in the
concentrate line.
Press the red icon in
the app to restart.