1.
TECHNICAL DATA
Unit
MK1
MK2
MK3
MK4
Primary
°C
90
45
90
45
90
45
90
45
Secondary
°C
25
25
25
25
Power
kW
27
8
43
12
58
17
95
27
Flow rate
Primary
m
3
/h
0.72
1.2
1.74
1.8
Secondary
4.5
5
6.5
11
Primary connections
Threading 3/4ʺ
Secondary connections
PVC union, female, solvent 50 to 63 mm
Operating temperature
Pool water
2 to 40 °C
Primary
water loop
45 to 90 °C
Max operating pressure
Primary
2 bars
Secondary
1.5 bars
2.
INSTALLATION OF THE HEAT EXCHANGER
2.1
Installation site
•
Heat exchangers must be installed in accordance with the rules of the art and the standards in effect.
•
The heat exchanger should be installed as close as possible to the boiler in order to minimise heat loss.
If this is not possible, you will need to lag the primary circuit pipes with thermal insulation.
•
For optimum heat exchange, the flows in the primary circuit and secondary circuit must cross within the
exchanger.
•
The heat exchanger must be connected directly to the boiler’s hot water production system. It should
under no circumstances be plumbed into an existing network (radiator circuit, residential hot water
supply circuit, etc.).
•
To mount the heat exchanger, use the support plate as a template to mark out the 4 holes that need to
be drilled in the wall.
2.2
Hydraulic connections
s
chematic
diagram
of
a
standard
installation
2020/11 - Indice de révision : J - Code : 33035
CHAUFFAGE ET DÉSHUMIDIFICATION
17/56