Rig Rat III Controller
Maintenance
Storage
Store the controller in a warm place as freezing the
electrolyte will damage the battery. As the battery
discharges, its freezing point rises. The rate of discharge
varies with the storage temperature. Higher temperatures
result in a faster discharge rate and hence shorter storage
times. While in storage the battery’s capacity should not be
allowed to fall below 50% of the fully charged state.
Note
It will take approximately one year for a battery to
discharge to 50% of its fully charged capacity.
Maintenance
The controller is designed to provide years of service with
only regular care and minimal maintenance. As regular
intervals inspect the instrument and check that it is operating
normally.
To clean the controller’s exterior, wash it with a mild soap
and clean water.