2.6
Set automatic output frequency
Command:
77 09 00 00 00 01 0C 00 10 26
Identifier
(1 byte)
Frame Length
(1 byte)
Address Code
(4 byte)
Command
(1 byte)
Data
(2 byte)
Checksum
(1 byte)
0x77
0x09
0x0C
0xXXXX
Response Command:
Identifier
(1 byte)
Frame Length
(1 byte)
Address Code
(4 byte)
Command
(1 byte)
Data
(1 byte)
Checksum
(1 byte)
0x77
0x08
0x8C
The data part is a 4-bit compressed BCD code. The allowed frequency range is 0-1000 (Hz), but higher
than 50Hz may cause unstable operation. Please try to select a frequency within 0-50Hz. When the set
automatic output frequency exceeds 1000, it is automatically set to 0. When the set automatic output
frequency is 0, the automatic output stops. When the set frequency is not a regular frequency, the
actual frequency may be slightly different from the set frequency, and the actual frequency obtained
through the serial port shall prevail. After setting, the save command (77 07 XXXXXXXX 0A YY) must
be sent to write to the internal storage, otherwise the previously saved configuration will be restored
after reset. The automatically output data content is the return information of reading all the data in
the hexadecimal command.
2.7
Set module address
Command:
77 0B 00 00 00 01 0F 12 34 56 78 2F
Identifier
(1 byte)
Frame Length
(1 byte)
Address Code
(4 byte)
Command
(1 byte)
Data
(4 byte)
Checksum
(1 byte)
0x77
0x0B
0x0F
0xXXXXXXXX
Response Command:
Identifier
(1 byte)
Frame Length
(1 byte)
Address Code
(4 byte)
Command
(1 byte)
Data
(1 byte)
Checksum
(1 byte)
0x77
0x08
0x8F
The module address is 8-bit hexadecimal data, and the factory default is 0x00000001, which will take
effect immediately after modification (including response commands). After setting, the save
command (77 07 XXXXXXXX 0A YY) must be sent to write to the internal storage, otherwise the
previously saved configuration will be restored after reset.
2.8
Query module address
Command:
77
07
00
00
00
00
1F
26
Identifier
(1 byte)
Frame Length
(1 byte)
Address Code
(4 byte)
Command
(1 byte)
Data
(0 byte)
Checksum
(1 byte)
0x77
0x07
0x00000000
0x1F
Response Command:
Identifier
(1 byte)
Frame Length
(1 byte)
Address Code
(4 byte)
Command
(1 byte)
Data
(4 byte)
Checksum
(1 byte)
0x77
0x0B
0x9F
0xXXXXXXXX
WF-WM410
WiFi Wireless High
Speed
High
Precision
Inclinometer
Bewis Sensing Technology LLC
www.bwsensing.com
Tel:
+86 18906177922
0x00
Succeeded
0xFF
Failed
0x00
Succeeded
0xFF
Failed