Страница 1: ...sing BuƩerfly Energy Systems please review installaƟon guide before installaƟon and retain for future reference BuƩerfly Energy Systems Air Intelligence Series InstallaƟon Guide For Outdoor MulƟ Head Systems BESM 24AO23 ...

Страница 2: ......

Страница 3: ...pliance may be changed without notice CONFORMITY AND RANGE GENERAL INFORMATION GENERA L INFORMATION Please read this owner s manual carefully before operating the unit and keep it carefully for consultation Product diagrams in this manual may appear different from your actual model The air conditioner you have purchased conforms with the following American Directives UL1995 Only use the air condit...

Страница 4: ... enter any ventilation or exhaust opening This many cause injury electrical shock fire or damage to the appliance 6 To prevent a possible fire do not block air intakes or exhaust in any manner 7 Do not stand or rest any object on top of the appliance 8 Do not operate if there is any damage to the appliance 9 The installation repairs and modifications to the appliance are only to be performed by a ...

Страница 5: ...t happen Wetting of air conditioner may cause the risk of electric shock Make sure not to wash your air conditioner in any case Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner Only use soft dry cloth moist cloth clean the air conditioner cabinet Collection of such waste separately for special treatment is necessary or its service agent or a simil...

Страница 6: ...ING TEMPERATURE RANGE GENERAL INFORMATION 4 TECHNICAL DATA GENERA L INFORMATION P L A B H Minimum power cable section 40 4 0 g mm mm mm mm mm L P H A B Fuse or air switch 2200 890 362 700 560 368 MODE BESM 24AO23 208 230V 1 60Hz mm2 Refrigerant gas R410A Electrical data Electricity supply Size and clearance c ...

Страница 7: ...onding to each other respective The appliance shall be installed in accordance with national wiring regulations Do not install the outdoor unit where it is exposed to the sunlight Note the above figures are only intended to be a simple e h t o t d n o p s e r r o c t o n y a m d n a e c n a i l p p a e h t f o m a r g a i d appearance of the units that have been purchased To the power supply To un...

Страница 8: ...ackaging check that the contents are intact and complete The outdoor unit must always be kept upright Handling must be done by suitably equipped qualified technical personnel using equipment that is for suitable the weight of the appliance 6 ...

Страница 9: ...Refrigerant fluid direction of flow 3 way valve 2 way valve Service inlet 2 Turn 8 Secure 7 Turn to open fully 2 Turn 8 Secure Valve cap 6 Open by 1 4 turn 7 Turn to open fully 2 Turn 8 Secure Valve cap Drain water hole Bottom frame Drain plug Hose available commercially inner dia 16mm Drain connecter Use bolts to secure the unit to a flat solid floor When mounting the unit on a wall or the roof m...

Страница 10: ... wall 200cm Air outlet side or above 30cm Space to the cover or above or more Space to the cover 50cm INSTALLER Use suitable instruments for the refrigerant R410A Do not use any other refrigerant than R410A Do not use mineral oils to clean the unit Contact service center before installation to avoid the malfunction due to unprofessional installation When picking up and moving the units you must be...

Страница 11: ...ecified on the nameplate The unit may bread down or the components may be burned out Are the lines and pipelines correctly installed The unit may bread down or the components may be burned out Has the unit been safely grounded Risk of electrical leakage Are the models of lines in conformity with requirements The unit may bread down or the components may be burned out Are there any obstacles near t...