22
PROBLEM
ORIGIN
SOLUTION
The flame does not ignite
No gas in the cylinder
Replace the bottle
The gas regulator is closed
Turning on the gas.
There’s no spark
Check that the spark plug has
not moved enough or it is very
dirty.
The burner is dirty
Carry out cleaning process
The flame is not steadily lit
The thermocouple is very dirty
or corroded.
Clean it with a toothbrush or a
scouring.
The thermocouple has moved
Bring
the
tip
of
the
thermocouple to about 2 mm
from the mesh of the burner
Refrigerator shuts off or
produces much smoke/odor.
The tube and burner are dirty
Perform cleaning process as
detailed in the operating
instructions
The refrigerator makes lot of
ice in the interior.
The doors do not close properly
Check the sealing of the doors.
You
must
defrost
the
refrigerator
The procedure of defrosting of
the refrigerator
There are liquids uncovered
inside
Use airtight containers
Refrigerator not cold enough.
The fireplace and burner are
dirty
Perform cleaning process as
detailed in the operating
instructions
The doors do not close properly Check the sealing of the doors
The temperature selector is in
the minimum position
Raise the temperature until it
yields just enough
The refrigerator does not have
the sufficient ventilation
Locate the appliance following
the instructions of this manual
The refrigerator is not level
Locate the appliance following
the instructions of this manual