![Butler NAV51.15 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/butler/nav51-15/nav51-15_instruction-manual_2835859012.webp)
INSTRUCTION, USE AND
MAINTENANCE MANUAL
GB
Page 12 of 96
9.2
Fixtures contained in the packing
The packing case contains also the fixtures box.
Check that all the parts listed are there.
Code
Description
N.
14620010
Clamp
1
B5119000
Long lever “A”
1
10.0 ELECTRICAL CONNECTION
EVEN THE TINIEST PROCEDURE
OF AN ELECTRICAL NATURE
MUST BE CARRIED OUT BY PRO-
FESSIONALLY QUALIFIED STAFF.
BEFORE CONNECTING THE MA-
CHINE MAKE SURE THAT:
• THE MAIN POWER RATING COR-
RESPONDS TO THE MACHINE
RATING AS SHOWN ON THE
MACHINE PLATE;
• ALL MAIN POWER COMPO-
NENTS ARE IN GOOD CONDI-
TION;
• THE ELECTRICAL SYSTEM
IS PROPERLY GROUNDED
(GROUND WIRE MUST BE THE
SAME CROSS-SECTION AREA
AS THE LARGEST POWER SUP-
PLY CABLES OR GREATER);
• MAKE SURE THAT THE ELEC-
TRICAL SYSTEM FEATURES A
CUTOUT WITH DIFFERENTIAL
PROTECTION SET AT 30 mA.
The machine is supplied with
5
m of free cable. A plug
corresponding to the following requirements must be
connected to the cable:
• Conformity to Norm
IEC 309
• 230/400 Volt – 16A
• 3P + Ground
• IP 44
On delivery, the machine is pre-set to operate at a
voltage of 400 V.
For any other type of power supply, ask the manufac-
turer at the time of purchase: a machine functioning
under the required voltage conditions will be prepared.
Only for version with inverter
• Conformity to Norm
IEC 309
•
400 Volt – 32A
•
3P + N + Ground
•
IP 44
La macchina, alla consegna, è predisposta per funzi-
onare con una tensione di 230/400 V-50 Hz.
For any other type of power supply, ask the manufac-
turer at the time of purchase: a machine functioning
under the required voltage conditions will be prepared.
FIT A TYPE-APPROVED (AS RE-
PORTED BEFORE) PLUG TO THE
MACHINE CABLE (THE GROUND
WIRE IS YELLOW/GREEN AND
MUST NEVER BE CONNECTED TO
THE PHASE LEADS). MAKE SURE
THAT THE ELECTRICAL SYSTEM
IS COMPATIBLE WITH THE RATED
POWER ABSORPTION SPECIFIED
IN THIS MANUAL AND APT TO
ENSURE THAT VOLTAGE DROP
UNDER FULL LOAD WILL NOT
EXCEED 4% OF RATED VOLTAGE
(10% UPON START-UP).
IN CASE OF A CHANCE SUPPLY
FAILURE, AND/OR BEFORE ANY
POWER SUPPLY CONNECTIONS,
MOVE THE PEDALS TO THE NEU-
TRAL POSITION.
7522-M004-1_B
NAV51.15 - NAV51T.15 - NAV51.15N