Press button
to select such procedure and bring
automatically the wheel into weight fitting position.
Fig. 33
1
2
3 4 5
6
KEY
1 – Only weight to be fitted
2 – Last program and last values used for the spin
3 – Residual dynamic unbalance value (if the value
is yellow, it is not recommended to carry out
ECO-WEIGHT procedure)
4 – Static unbalance value (if the value is yellow,
it is not recommended to carry out ECO-
WEIGHT procedure)
5 – Residual dynamic unbalance value (if the value
is yellow, it is not recommended to carry out
ECO-WEIGHT procedure)
6 – Arrows indicating the weight fitting point with
distance-diameter caliper arm
Press the brake pedal and fit the adhesive weight inside
pliers as shown in
Fig. 34
.
Fig. 34
Fit the adhesive weight
in the pliers of the gauge rod
Pull out the gauge rod until the arrows (
Fig. 33 ref. 6
)
turn green.
Fig. 35
Fit weight on the position
where pliers touches the wheel
At the end of the procedure, the wheel balancing condi-
tions can be checked by performing a trial spin.
The ECO-WEIGHT procedure has now been completed.