General Operating Instructions (please read)

Important:

Always operate the compressor within its maximum pressure rating.  Refer to 

the specifications section of this manual for details.  Operations exceeding 

maximum pressure rating will result in damage to air compressor and 
void warranty.

Your air compressor is equipped with an automatic thermal overload protector.  
This feature is designed to protect the air compressor from over-heating and 
causing permanent damage to your air compressor.  The thermal overload 
protector will automatically cut off power to air compressor should internal 
operating temperature rise above safe levels during excessive use.

Should at any time during usage your air compressor automatically shut down, 
do not attempt to restart air compressor.  Turn off the power switch.  The 
automatic thermal overload protector will automatically reset when internal 
temperature of the air compressor drops to safe levels.  After allowing air 
compressor to cool off for about 15 minutes, you can safely resume usage of the 
air compressor by turning on the power switch – your warranty will be void if this 
instruction is not followed.

It is strongly recommended that you keep the vehicle’s engine running while 
using the air compressor to prevent discharge of your vehicle’s battery.  This 

means you should ONLY OPERATE THE AIR COMPRESSOR IN WELL VENTILATED 
AREAS.  Compressor performance is also enhanced when operating with the 

vehicle’s engine running.

Please note that you may experience a slight delay (about 3 sec) to the 
compressor’s motor starting when the compressor is pressurised, (i.e. when 
there is back pressure in the air line) This is a normal delayed reaction, not a 
compressor on/off switch malfunction

1.

2.

3.

4.

5.

Please read and follow the operating instructions carefully to understand and get 
the most from your Black Max Compressor.

Содержание Black Max 55X12

Страница 1: ... Black Max Compressor Page 1 ...

Страница 2: ... Black Max Compressor Page 2 ...

Страница 3: ...3 Congratulations on your purchase of the Bushranger Black Max Compressor To take full advantage of this product please read this manual carefully before using Retain this manual for future reference for installation and warranty ...

Страница 4: ...c thermal overload protector will automatically reset when internal temperature of the air compressor drops to safe levels After allowing air compressor to cool off for about 15 minutes you can safely resume usage of the air compressor by turning on the power switch your warranty will be void if this instruction is not followed It is strongly recommended that you keep the vehicle s engine running ...

Страница 5: ...is in the Off position For first time use ensure air filter is fitted correctly see page 7 Attach the Red battery clamp to the Positive terminal of the battery and the Black battery clamp to the Negative terminal of the battery ensuring you have made a good connection Always keep your vehicle s engine running while operating compressor to avoid draining your vehicle s battery Always make sure the ...

Страница 6: ...tor collar to stop deflation The 50mm in line gauge provides convenient monitoring of tyre pressure when deflating or inflating This eliminates switching back and forth between a hand held pressure gauge and the compressor Please note that during inflation and deflation due to air velocity the pressure gauge cannot provide accurate readings Momentarily stop inflation to obtain accurate pressure re...

Страница 7: ...Fitting Air Filter Unit Do not disassemble Do not attempt repairs or modifications Your warranty will be void if this instruction is ignored Do not use this product in an area where it can fall or be pulled into water or other liquids The base tray is fitted to place a barrier between the compressor sandy or dusty ground plus provide a stable operating platform therefore keep the tray clean at all...

Страница 8: ...ressor is equipped with an Automatic Reset Thermal Protector can automatically restart after the thermal protector resets Always turn off the power when thermal protector becomes activated Never Point any air nozzles toward another person or any part of the body After use always release pressure from the hose by turning ON OFF switch to OFF Press trigger on the tyre gun this releases pressure in s...

Страница 9: ... thermal overload switch will reset Thermal Overload Protector cuts out repeatedly 1 Lack of proper ventilation ambient temperature is too high 2 Compressor valves failed 1 Move compressor to well ventilated area or area with lower ambient temperature 2 Replace compressor Excessive knocking or rattling 1 Worn bearing on eccentric or motor shaft 2 Cylinder or piston ring is worn 1 Replace compresso...

Страница 10: ...tres per minute 30 mins 40psi 24 C 200 psi 28 Amps 30A Fused 40 Amps Yes 25 x 19 x 13cm 3 9 kg Part number Description Motor voltage Motor type Max Working Pressure Max flow rate 0 psi 13 8V Max Duty Cycle Max restart pressure Maximum Draw In line fuse Auto reset Thermal Protection Dimensions L x W x H Net weight ...

Страница 11: ...e laws including unusual improper or negligent use or misuse or overloading d misuse or neglect of the Kingsley product including improper repair or maintenance or failing to repair or maintain e alteration abuse acts of nature terrorism vandalism collision road hazards or adverse conditions 4 Making a claim Please immediately contact us as soon as you become aware of a possible defect in the King...

Страница 12: ... Max Compressor Page 12 bushranger com au Free Call 1800 654 767 Australia only International 61 2 8700 0400 Fax 61 2 8700 0499 Email sales kingsleyenterprises com au Address 6A Brooks Road Ingleburn NSW 2565 ...