background image

 

 
INSTALLATION INTO A CAVITY 

DC-X fridges are designed to be installed in a cavity. A gap of minimum 40mm is recommended for the rear. Refer to 
the following table for the recommended cut-out dimensions. If you are using the mounting kit, allow an extra 5mm 
width for the mounting kit frame and screws. 
 

MODEL 

CUT-OUT CAVITY DIMENSIONS (MM) 

WIDTH

 

DEPTH

 

HEIGHT

 

DC50-X 

385 

495 

530 

DC65-X 

455 

515 

530 

DC85-X 

480 

550 

630 

DC130-X 

530 

550 

755 

 

 
EFFICIENT OPERATION 

 

 

 

 

 

 

 

VENTILATION 

Ventilation will have a significant impact on the efficient operation of your fridge. A minimum of 2 vents need to be 
provided from the rear of the fridge cavity to the outside environment, or to the general area where the fridge is 
located. The vents should be located at the bottom and top of the fridge cavity and have a free cross section of 
minimum 200cm2 each. By providing free air flow to the compressor area your cooling system will remove heat 
faster and the fridge will operate more efficiently. 
 

MOUNTING KIT 

The mounting kit is first affixed to the side and top of the fridge cabinet using the screws provided. 
Once the fridge has been connected to the power supply and moved into its final position, the mounting kit can be 
affixed to the front of the cavity. 
 
 

OPERATING THE FRIDGE 

 

 

 

 

 

 

THERMOSTAT 

 

The cooling level can be set between 1 and 7. 

 

7 is the coldest setting and 1 is the warmest.  

 

EQUALISING THE FRIDGE 

During the first 24 hours of operation, your compressor will operate for longer than usual. This process allows the 
internal air temperature, food, drinks, condenser and insulation to equalise.  
 

ENERGY SAVING TIPS 

 

Have a much ventilation as possible – the more the better. 

 

Keep the fridge out of direct sunlight whenever possible 

 

Only open the fridge or freezer door when necessary 

 

Allow hot food to cool down before placing inside the fridge 

 

Defrost the fridge as soon as a layer of ice forms 

 

Set the fridge to be only as cold as necessary 

 
USING THE FRIDGE IN EXTREME HEAT 

If you are using your fridge in a very hot area or situation, removing the drip tray will improve cold air circulation 
throughout the fridge cabinet. Note the DC130-X and DC85-X models do not have a drip tray. 

 
 
 
 
 
 
 
 
 
 

Содержание DC-X Series

Страница 1: ...User Manual Operating Instructions DC X Fridges CARAVAN MARINE RV OFFGRID User Manual and 12 24V Fridge Freezer Product Specifications Read user manual before operating your fridge freezer DC 85X DC 130X ...

Страница 2: ...mpleted by a suitably trained professional only POWER SUPPLY Your fridge must be connected to a stable and regulated 12 V or 24 V DC power supply only The compressor will automatically detect which voltage is present adjust accordingly If you are using a generator or other power supply the output must be a pure sine wave Any fluctuations in generator current may damage the compressor WIRING For op...

Страница 3: ... KIT The mounting kit is first affixed to the side and top of the fridge cabinet using the screws provided Once the fridge has been connected to the power supply and moved into its final position the mounting kit can be affixed to the front of the cavity OPERATING THE FRIDGE THERMOSTAT The cooling level can be set between 1 and 7 7 is the coldest setting and 1 is the warmest EQUALISING THE FRIDGE ...

Страница 4: ...en opening or closing the freezer door if ice has been allowed to accumulate in this area Keep the door of the fridge ajar when the fridge is not in use to allow fresh air to circulate inside the fridge compartment DEFROSTING Defrosting needs to be carried out when the ice layer reaches a thickness of 5mm Turn off the power to the fridge and move your food and beverages to another cool place Do no...

Страница 5: ...wards so that the plastic latch is just touching Reaffix in this position See diagram below CORRECT 0 1MM GAP INCORRECT 2MM GAP RUBBER SEALS 1 There are magnets inside the rubber seal which pull towards the metal fridge cabinet to keep it airtight 2 After you have adjusted your door latch check to see that the rubber seal is making contact with the fridge cabinet on all 4 sides If there is even a ...

Страница 6: ...wiring checked by an electrician when under a 10 A load TROUBLESHOOTING Check Correct power supply The voltage to the compressor is still 12V when a 10 A load is placed on the wire The fan is operating The polarity of the connections are correct There is adequate ventilation to the rear of the fridge The fuse is not blown The rubber door seal is touching the fridge cabinet all the way around on al...

Страница 7: ......

Страница 8: ......

Страница 9: ...Exterior Ventilation Interior Ventilation Option 1 Interior Ventilation Option 3 min 200cm2 min 40mm min 40mm min 40mm min 40mm min 40mm Interior Ventilation Option 4 Interior Ventilation Option 2 min 200cm2 min 150mm min 150mm ...

Страница 10: ...NOTES ...

Страница 11: ...shipping charges related to returning the repaired product to the customer This warranty does not apply to damage or wear to the product caused by accident abuse misuse neglect unauthorized alteration or repair or if the product was not used in accordance with Bushman printed installation and operating instructions To obtain service under this warranty the defective product must be returned to Bus...

Страница 12: ...For after sales service and enquiries please contact Bushman Fridges 3 Contour Close Research VIC 3095 03 9437 0737 info bushman com au ...

Отзывы: