OPERATION
PHDHF / PHDHC 03/20
Operation Section 4-22
© 2020 Alamo Group Inc.
O
PE
R
AT
IO
N
TROUBLE
POSSIBLE CAUSE
POSSIBLE REMEDY
Excessive Hydraulic
Restricted Hydraulic lines
Clean or replace hydraulic lines.
Oil Heating
Oil passing over relief valve
Decrease down pressure applied
too frequently.
to auger.
Insufficient hydraulic oil
Contact power unit manufacturer
reservoir size to pump
for increasing reservoir size or
output ratio.
adding oil cooler.
Dirty or contaminated
Replace power unit hydraulic oil
hydraulic oil.
and hydraulic oil filters.