7.1.4
Setting
the
target
value
needle
on
the
contact
vacuum
gauge
The
target
values
are
set
via
the
adjustment
lock
in
the
sight
disc
using
the
adjustment
key
(enclosed,
can
be
found
on
the
side
of
the
cable
socket).
To
adjust
the
set
pointer,
place
the
adjustment
key
at
the
adjustment
lock,
press
it
in
and
set
the
required
set
point.
Fig.
10:
Contact
vacuum
gauge
The
set
pointers
of
the
limit
switches
can
be
adjusted
freely
throughout
the
scale
range.
For
reasons
of
switching
accuracy,
switching
safety
and
service
life
of
the
mechanical
measuring
systems,
the
switching
points
should
be
between
10
%
and
90
%
of
the
measuring
range.
Set
the
set
pointers
to
desired
activation
and
shutdown
pressures.
The
clearance
between
the
two
set
pointers
is
approx.
10%
of
the
scale
range.
When
the
lower
switching
point
is
reached,
the
vacuum
pump
is
switched
off
and
correspond
‐
ing,
when
the
upper
switching
point
is
reached,
again
switched
on.
Factory
settings
of
the
switching
points:
lower
switching
point:
‐
0.9
bar
(90
%)
upper
switching
point:
‐
0.8
bar
(80
%)
NOTICE
The
recommended
minimum
clearance
between
two
contacts
is
10%
of
the
measuring
span.
The
switch
hysteresis
is
2
…
5%.
Set
pointers
Removable
adjustment
key
Adjustment
lock