6
|
Installation
16
/
46
0870169324
_VD
0025
‐
0100G_
‐
0006_IM_en
6.2.2
Gas
outlet
CAUTION
Health
risk!
The
discharged
gas
contains
small
amounts
of
oil.
Ensure
sufficient
ventilation
in
the
installation
room
when
the
air
is
routed
into
rooms
where
there
are
people.
Connect
the
gas
outlet
line
to
both
gas
outlet
openings
of
the
vacuum
pump
if
required.
Dimensions,
see
scale
drawing
in
the
appendix;
connection
size
of
thread:
G
1
¼“.
Ensure
that
the
discharged
gas
can
flow
off
unhindered.
Never
close
the
gas
outlet
line,
do
not
throttle
it
and
do
not
use
it
as
a
compressed
air
source.
If
the
air
taken
in
is
not
discharged
to
the
environment
in
the
direct
proximity
of
the
vacuum
system,
observe
the
following:
Place
the
gas
outlet
line
dropping
towards
the
vacuum
system
or
install
a
liquid
separator
or
a
siphon
with
a
drain
valve
so
that
no
liquid
can
flow
back
into
the
vacuum
system.
Fig.
7:
Gas
outlet