the base plate, through the two rubber gaskets (Ref. 47)
and into the plastic cover. Roll the pump onto its base
plate and replace the electrical junction box cover.
Insert the rubber bushing (Ref. 43), spacer (Ref. 46)
and sleeve into the top of the plastic cover. On the
SV1010 and SV1016, screw the socket head cap screw
(Ref. 42) into the pump. On the SV1025 and SV1040,
screw the stud (Ref. 45) and eye bolt (Ref. 42) into the
pump (see Fig. 17).
6.4
Vanes
Slide the vanes (Ref. 6) into the vane slots. Make sure
the radius edge is matched to the contour of the cylin-
der bore (see Fig. 2).
6.5
Endplate, Opposite Motor Side
Install the opposite motor side endplate (Ref. 18) to the
cylinder. Secure with four M6 socket head cap screws
and lockwashers (Ref.19/20).
6.6
Filter Cover and Plastic Cover
Install a new filter cover gasket (Ref. 22). Do not use
the old gasket as it does not seal well when reused.
Position the filter element (Ref. 27), retaining spring
(Ref. 25) and filter cover (Ref. 24) in place and secure
with three socket head cap screws and copper washers
(Ref. 28/29).
Position the two rubber feet (Ref. 71) against the filter
cover and slide the plastic cover (Ref. 70) over the filter
cover, sandwiching the rubber feet between the filter
cover and plastic cover while tightening the two socket
head cap screws.
7.0
LIMITED STANDARD WARRANTY
Busch, Inc. warrants that all products furnished by it are
free from defects in material and workmanship at the
time of shipment for a period of 18 months from the
date of shipment, or 12 months from the date of instal-
lation, whichever occurs first. Claims must be made
during that period and are limited to the replacement or
repair of parts claimed to be defective.
In the case of components purchased by Busch, Inc.,
such as starters, controls, mechanical seals, motors,
couplings, etc., the warranty of that manufacturer will be
extended to the purchaser in lieu of any warranty by
Busch, Inc. The replacement of wear items including,
but not limited to, seals, bearings, couplings, exhaust
cover gaskets, etc., made in connection with normal
service, are not covered by this Warranty.
The Limited Standard Warranty is valid only when the
product has been properly installed, used in a normal
manner, and serviced according to the operating man-
ual. This warranty shall not extend to products that
have been misused, neglected, altered, or repaired
without factory authorization during the warranty period.
We highly recommend the use of Busch parts to
achieve documented performance and efficient opera-
tion. The use of parts other than Busch could limit the
life expectancy of the equipment and could void any
warranties if they are the cause of any damage.
Operating conditions beyond our control such as
improper voltage, excessive ambient temperatures, or
other conditions that would affect the performance or
life of the product will also cause the warranty to
become void.
Permission to return parts for warranty repair must be
obtained, and all returns must be prepaid to the factory.
If, after examination, the product or part is found to be
defective, it will be repaired or replaced on a no-charge
basis and returned, FOB the factory. If it is determined
that the Warranty has not been breached by Busch,
Inc., then the usual charges for repair or replacement
will be made, FOB the factory. Parts or products that
are obsolete or those made to special order are not
returnable.
This Limited Standard Warranty applies only to the
above and is for the period set forth. Busch, Inc.'s max-
imum liability shall not, in any case, exceed the contract
price for the product, part, or component claimed to be
defective; and Busch, Inc. assumes no liability for any
special, indirect, or consequential damages arising
from defective equipment.
THERE ARE NO WARRANTIES IMPLIED OR
EXPRESSED THAT EXTEND BEYOND THOSE
CONTAINED IN THIS LIMITED STANDARD
WARRANTY.
Note:
For extended warranties on your new equipment
contact Busch Headquarters at 1-800-USA-PUMP.
7
Fig. 17 - Lift Ring