13 | Technical Data
36 | 40
Instruction Manual R5 RD 0200-0360 A_EN_en
RD 0300 A
RD 0360 A
Nominal pumping speed
(50Hz / 60Hz)
m³/h
250 / 300
300 / 360
ACFM
147 / 177
177 / 212
Ultimate pressure
(without gas ballast valve)
hPa (mbar) abs.
0.1
TORR
0.075
Ultimate pressure
(with gas ballast valve)
hPa (mbar) abs.
0.5
TORR
0.375
Nominal motor speed
(50Hz / 60Hz)
min
-1
1500 / 1800
RPM
Permitted motor speed range
min
-1
1200 … 1800
RPM
Nominal motor rating
(50Hz / 60Hz)
kW
5.5 / 6.6
5.5 / 6.6
HP
- / 8.9
- / 8.9
Power consumption at 100 mbar –
75 TORR (50Hz / 60Hz)
kW
4.6 / 5.6
5.1 / 6.3
HP
- / 7.5
- / 8.4
Power consumption at ultimate
pressure (50Hz / 60Hz)
kW
2.4 / 3.0
2.8 / 3.2
HP
- / 4.0
- / 4.3
Noise level (ISO 2151)
(50Hz / 60Hz)
dB(A)
68 / 72
70 / 72
Water vapor tolerance max. (with
gas ballast valve) (50Hz / 60Hz)
hPa (mbar)
40 / 100
TORR
- / 75
Water vapor capacity (with gas
ballast valve) (50Hz / 60Hz)
kg / h
8,1 / 17,7
9,9 / 25
Lbs. / h
17.8 / 39
21.8 / 55.1
Max. allowable pressure in the oil
mist separator
hPa (mbar) abs.
1600
TORR
1200
Max. allowable gas inlet
temperature
°C
≤
50 hPa (mbar) abs.
►
150
°F
≤
37.5 torr
►
302
°C
>
50 hPa (mbar) abs.
►
80
°F
>
37.5 torr
►
176
Ambient temperature range
°C
5 ... 40
°F
41 … 104
Ambient pressure
Atmospheric pressure
Oil capacity
L
7
qts.
7.5
Weight approx.
Kg
190
Lbs.
419