12 | Troubleshooting
34 | 40
Instruction Manual R5 RD 0200-0360 A_EN_en
Problem
Possible Cause
Remedy
The machine runs very noisily.
Worn coupling (CPL).
●
Replace the coupling (CPL).
Stuck vanes.
●
Repair the machine (contact
Busch).
Defective bearings.
●
Repair the machine (contact
Busch).
The machine fumes or expels
oil droplets through the gas
discharge.
The exhaust filters (EF) are
partially clogged.
●
Replace the exhaust filters
(EF).
An exhaust filter (EF) with o-
ring is not fitted properly.
●
Ensure the correct position
of the exhaust filters (EF)
and the o-rings.
The float valve (FV) does not
work properly.
●
Check the float valve.
●
Repair the machine (contact
Busch).
The oil is black.
Oil change intervals are too
long.
●
Flush the machine (contact
Busch).
The inlet filter (optional) is
defective.
●
Replace the inlet filter.
The machine runs too hot.
●
See problem "The machine
runs too hot".
The oil is emulsified.
The machine sucked in liquids
or significant amounts of
vapor.
●
Flush the machine (contact
Busch).
●
Clean the filter of the gas
ballast valve (GB).
●
Modify the operational
mode (see Conveying
Condensable Vapors [
For the solution of problems not mentioned in the troubleshooting chart contact your Busch