Storage | 4
0870201428_RA0165-0305D_O2_-0004_IM_en
9 / 36
4
Storage
• Seal all apertures with adhesive tape or reuse provided caps.
Version with water-oil heat exchanger:
• Make sure that the cooling water has been completely removed, see
.
If the machine is to be stored for more than 3 months:
• Wrap the machine in a corrosion inhibiting film.
• Store the machine indoors, dry, dust free and if possible in original packaging
preferably at temperatures between 0 ... 40 °C.
5
Installation
WARNING
Lack of oxygen regulation knowledge.
Risk of fire!
• Installation, commissioning and maintenance must only be carried out by qualified
personnel who are informed about the applicable safety regulations and trained in the
handling of oxygen.
• Accident prevention regulations or methods must imperatively be complied with.
Seek further information:
- European Industrial Gases Association “EIGA” www.eiga.eu (EIGA SAG NL 79/04).
- Berufsgenossenschaft Rohstoffe und chemische Industrie "BG RCI”
(Merkblatt M 034 Sauerstoff).
5.1 Installation Conditions
WARNING
The machine is not absolutely gas tight.
Risk of fire!
• The installation area must be aired in such a way so as to prevent unacceptable levels
of oxygen.
NOTICE
Use of the machine outside of the permitted installation conditions.
Risk of premature failure!
Loss of efficiency!
• Take care that the installation conditions are fully complied with.