11 | Troubleshooting
26 / 32
0870207738_RA_RC0400-0630C_USA_-_IM_en
The oil is emulsified.
The vacuum pump sucked in
liquids or significant
amounts of vapour.
• Flush the vacuum pump
(contact Busch).
• Clean the filter of the gas
ballast valve (GB).
• Modify the operational
mode (see
Conveying
Condensable Vapours
[
►
14]
).
For the solution of problems not mentioned in the troubleshooting chart contact your