6 | In Operation
16 / 44
Instruction Manual PLUS Master Control R5 PLUS_EN_en
NOTE
If one or more pumps are in “Auto” mode and the button indicating the pump name
(VP1, VP2,...) under the pump symbol flashes.
This indicates a communication problem.
• In this case, check the Ethernet settings in the control interface of the corresponding
pump(s) and acknowledge alarms related to communication if any. Refer to the Warn-
ing/Alarm Acknowledgment procedure described in the instruction manual(s) of the
respective pump(s).
6
In Operation
CAUTION
During operation the surface of the suction and exhaust connections may reach temper-
atures of more than 70°C.
Risk of burns!
• Avoid contact with these surfaces during and directly after operation.
NOTE
In the following CAUTION message(s), the term “machine” refers to each of the PLUS
pumps integrated into the system.
CAUTION
Remove covers during operation.
Risk of burns!
• If a cover is removed when the machine is operating, avoid contact with surfaces in-
side the acoustic cabinet.
CAUTION
Noise of running machine.
Risk of damage to hearing!
If persons are present in the vicinity of a non noise insulated machine over extended pe-
riods:
• Make sure that ear protection is being used.
6.1 System Activation
WARNING
The machines may start without notice.
Risk of severe injury!
As soon as the “PLUS Master regulation” button is switched to “Run”:
• Make sure that the machines are fully operational.
Содержание PLUS Master Control