Installation | 5
Instruction Manual MINK MM 1402-1502 AV_EN_en
9 / 28
5
Installation
5.1 Installation Conditions
WARNING
Gas tight version:
The machine is not absolutely gas tight, possible leakages of dangerous media.
Risk of poisoning!
Risk of infection!
• Make sure that the ambient atmosphere of the machine is sufficiently ventilated.
Closed air cooling systems are not suitable and therefore prohibited.
NOTICE
Use of the machine outside of the permitted installation conditions.
Risk of premature failure!
Loss of efficiency!
• Take care that the installation conditions are fully complied with.
~1 m
~1 m
~1 m
~1 m
Other values may apply after Busch approval
• Make sure that the environment of the machine is not potentially explosive.
• Make sure that the ambient conditions comply with the
• Make sure that the environmental conditions comply with the protection class of the
motor and the electrical instruments.
• Make sure that the installation space or location is vented such that sufficient cooling
of the machine is provided.
• Make sure that cooling air inlets and outlets are not covered or obstructed and that
the cooling air flow is not affected adversely in any other way.
• Make sure that the oil sight glass (OSG) remains easily visible.
• Make sure that enough space remains for maintenance work.