Troubleshooting | 11
Instruction Manual MINK MM 1402-1502 AV_EN_en
23 / 28
IS
CPL
Problem
Possible Cause
Remedy
The machine does not start. The motor is not supplied
with the correct voltage.
• Check the power supply.
The motor is defective.
• Replace the motor.
The coupling (CPL) is defec-
tive.
• Replace the coupling
(CPL).
The machine does not reach
the usual pressure on the
suction connection.
The inlet screen (IS) is par-
tially clogged.
• Clean the inlet screen (IS).
The inlet filter cartridge (op-
tional) is partially clogged.
• Replace the inlet filter car-
tridge.
Internal parts are worn or
damaged.
• Repair the machine (con-
tact Busch).
The machine runs very noisily. Worn coupling (CPL).
• Replace the coupling
(CPL).
Oil level too low.
• Top up oil.
Defective bearings.
• Repair the machine (con-
tact Busch).
The machine runs too hot.
Insufficient cooling.
• Remove dust and dirt
from the machine.
Ambient temperature too
high.
• Observe the permitted
ambient temperature, see
Temperature of the process
gases at the inlet too high.
• Observe the permitted
gas inlet temperature, see
Oil level too low.
• Top up oil.
For the solution of problems not mentioned in the troubleshooting chart contact your
Busch representative.
Содержание MINK MM 1402 AV
Страница 27: ...Note ...