Interrupt the ohmic resistance
●
Make sure that a fault indication is released in the system control and the machine is shut down
automatically
●
Reconnect the variable ohmic resistance
●
Switch on the machine again
●
Short circuit the variable ohmic resistance
●
Make sure that a fault indication is released in the system control and the machine is shut down
automatically
●
Remove the short circuit
●
Remove the variable ohmic resistance
●
Reconnect the resistance thermometer Pt100 to the temperature transmitter as shown (white
cable to pin 3, first red cable to pin 5, second red cable to pin 6)
3 = White; 5 = Red; 6 = Red
●
Firmly close the terminal box with transmitter (TSA) with the lid