5 | Installation
20 | 40
Instruction Manual MINK MM 1104-1142 BV ATEX_EN_en
Delta connection, multi-voltage motor with 12
pins (middle voltage):
4
4
4
5.7
Electrical Connection of the Monitoring Devices
NOTE
In order to prevent potential nuisance alarms, Busch allows that the control system is
configured with a time delay of 2 seconds.
NOTE
The accessories below are considered as standard.
If other specific components should be used, refer to the instruction manual of the accessory
in question.
WARNING
If the monitoring sensors are not used.
Risk of explosion!
●
Always use the mandatory monitoring sensors.
5.7.1
Wiring Diagram Resistance Thermometer
Version with temperature monitoring (TSA):
●
Execute the interface for the temperature measuring system in the plant control system
according to the
10] and the manufacturer's instructions. Trip switch
temperature shown on the nameplate (NP) of the machine.
PT100 (stainless steel): 0651 141 747
WIKA Alexander Wiegand SE & Co. KG
Reference: TR40 Pt100/B/3
Transmitter: 0645 139 055
Hauser SE + Co. KG
Reference: TMT 181-B
Ignition protection type b1
According EN ISO 80079-37
Maintenance procedure:
Yearly: Calibration and function check
1 =
+
; 2 =
-
; 3 = White ; 5 = Red ; 6 = Red