Technical Data | 9
Installation and Retrofit Instructions DOLPHIN LM 0530-0800 A, LT 0320-0630
A_EN_en
21 / 24
9
Technical Data
Below additional technical data once the variable-frequency drive has been installed on
the motor.
The technical datas of the machine in the original instruction manual remain valid after
the retrofitting.
LM 0530-0800 A with VFD - LT 0320-0630 A with VFD
Allowed frequency range
34 – 60 Hz
Installation altitude
100% load capacity (no derating) up to 1000 m;
Derating 1% / 100 m at 1000 … 2000 m
Supply network
TN- and TT-network
(cannot be used with corner grounded networks)
Immunity
EN 61800-3, 2nd environment
Emissions
EN 61800-3, category C2 as standard
Содержание LM 0530 A
Страница 22: ...Note ...
Страница 23: ...Note ...