Installation | 5
Instruction Manual R5 KD 0012-0020 A_EN_en
9 / 24
5.3 Filling Oil
NOTICE
Use of an inappropriate oil.
Risk of premature failure!
Loss of efficiency!
• Only use an oil type which has previously been approved and recommended by Busch.
For oil type and oil capacity see
.
Check oil level
1x o-ring, part no.:
0486 000 590
Max. admissible
torque: 12 Nm
5.4 Electrical Connection
DANGER
Live wires.
Risk of electrical shock.
• Electrical installation work must only be executed by qualified personnel.
• Make sure that the power supply for the motor is compatible with the data on the
nameplate of the motor.
• The electrical installation must comply with applicable national and international standards.
• Provide a lockable disconnect switch on the power line so that the machine is com-
pletely secured during maintenance tasks.
• Provide an overload protection according to EN 60204-1 for the motor.
• Busch recommends installing a D-curve circuit breaker.
• Make sure that the motor of the machine will not be affected by electric or electro-
magnetic disturbance from the mains; if necessary seek advice from Busch.
• Install the capacitor and connect it to the capacitor connection (CC), see
.
• Electrically connect the motor.
Содержание KD 0012 A
Страница 23: ...Note ...