Troubleshooting | 11
Instruction Manual Supplement DOLPHIN VL Systems ATEX_EN_en
27 / 36
The machine does not reach
the usual pressure on the
suction connection.
Suction or discharge lines
too long or section diameter
too small.
• Use larger diameter or
shorter lines.
• Seek advice from your lo-
cal Busch representative.
The operating liquid is too
warm.
(the characteristic curves are
based on 15°C warm water
as operating liquid, with
higher temperatures the
achieved pressure and the
flow rate deteriorate)
• Adjust cooling liquid flow
rate to reduce the tem-
perature of the operating
liquid.
• Check heat exchanger for
blockage.
• Check cooling liquid sup-
ply temperature and flow
Partial clogging in the suc-
tion, discharge or pressure
line.
• Remove the blockage.
If an inlet screen is installed,
it can be partially clogged.
• Clean the inlet screen.
Leakage occurring in the
system.
• Check the joints are
sealed sufficiently.
Separator liquid level not
maintained.
Partial blockage in the liquid
outlet/overflow line.
• Remove the blockage.
Control switch operation.
• Check switch to solenoid
valve control.
• Check switch operation –
replace if damaged.
• Check solenoid valve op-
eration – replace if dam-
aged.
Y-strainer clogged.
• Clean the Y-strainer
screen.