The following instructions for connection to the discharge only apply if

the drawn gas is discharged by the vacuum pump into a suitable envi-

ronment.

Make sure that the protection that was attached to prevent

penetration of particles during transport has been removed before

the vacuum pump is connected to the vacuum line

Make sure that the nominal diameter of the exhaust line is at least

equal to the diameter of the exhaust flange of the vacuum pump

to prevent a drop in the performance of the vacuum pump in the

case of a smaller cross-section

Make sure that the vacuum pump is connected with leakproof lines

CAUTION

When the discharge lines have been connected, make sure that the 

system does not leak. Leakages of dangerous substances must be

prevented!

Make sure that the discharge line is mounted in such a way that

condensate cannot penetrate into the pump (siphon trap, gradient)

Make sure that no shut-off devices are mounted in the discharge

line

Make sure that the discharge lines do not exercise any force on the

discharge flange. Mount bellows if necessary

The discharge flange has the following dimension:

DN 63 ISO-K

In the case of long discharge lines the line cross-section should be lar-

ger than the discharge flange to prevent a drop in the performance of

the vacuum pump. If you have any doubts, contact your Busch repre-

sentative.

Cooling water connection

The cooling water is generally connected with a hose. 
The cooling water outlet must be unpressurised.
Connection diameter: 3/8 NPT

Nitrogen connection

The nitrogen is connected with a pipe (leakproof against oxygen).
Connection diameter: 1/4 NPT

Electrical connection/ Checks

Make sure that the regulations of the Electromagnetic

Compatibility Directive 2014/30/EU as well as standard EN norms,

safety directives and especially local and national regulations are

observed (this is the responsibility of the manufacturer of the

system into which the vacuum pump is integrated according to the

Declaration of Conformity)

Make sure that the mains power supply corresponds to the data on

the nameplate of the motor

Make sure that an overload cut-out according to EN 60204-1 is

provided for the motor

Make sure that the drive of the vacuum pump is not disturbed by

any electric or electromagnetic interferences. If you have any

doubts, contact your Busch representative

Installation

Mounting

Make sure that the “Necessary installation instructions” are

followed

Fasten or install the pump at its final installation site

Electrical connection

Three phase motor connection

Star-star connection (Low voltage)

DS 8161 F

Installation and start-up

Page 11

0870235853

 (En)

T9

T8

T6

T7

T5

T3

T1

T2

T4

P1 

P2

P3 

P4

T7

T8

T9

T

T2

T3

L1

L3

L2

T4

T5

T6

WARNING

Risk of electrocution, risk of damage.

Electrical installation must be performed by a suitably qualified 

electrician who knows and follows the following regulations:

-

IEC 364 or CENELEC HD 384 or DIN VDE 0100,

-

IEC Report 664 or DIN VDE 0110,

-

VBG 4 or corresponding national regulations on accident 

prevention

CAUTION

The circuit diagrams described below conform to the 

standard. Other circuit diagrams might be used. This 

depends on the particular order and the market.

Risk of damage to the motors!

Check the connection of the motors inside the terminal 

box according to the circuit diagram.

Motor of screw pump DS is connected at factory.

CAUTION

When connecting up the wires into the terminal box: please

make sure the tightening torque of 2 Nm is adhered to and

check with a calibrated torque wrench (Nuts M6).

Содержание COMBI COBRA DP 600 C

Страница 1: ...liers Busch S A Zone industrielle 2906 Chevenez Switzerland 0870235853 _en Original instructions Modi cations reserved 07 12 2020 Instruction manual COMBI Screw Vacuum Pumps and Boosters COBRA DS 8161...

Страница 2: ...ogram 19 Weekly 19 Monthly 19 Yearly 19 Every 16 000 hours of operation at the latest after 4 years 20 Lock Out Tag Out procedure 20 Safety Lockout procedure 20 Checking the oil 20 Checking the oil le...

Страница 3: ...re reducer CWC Cooling water connection DGC Nitrogen connection OSG Oil sight glass CAO Extracting ventilator MB On off switch Main circuit breaker ESS Emergency stop switch EMO RF Ventilator PLC PLC...

Страница 4: ...switch cooling water HE Heat exchanger CWV Regulating valve coolingwater FS Flow switch booster OSG3 Oil sight glass OSG1 Oil sight glass PRV Nitrogen regulatingvalve CLP Glycol circulatingpump TS2 Te...

Страница 5: ...cator MB OSG4 Oil level indicator MB PGI Process gas inlet PGO Process gas outlet PRV Nitrogen regulating valve TR Temperature regulator 55 C TS1 Temperature switch oil temperature 120 C TS2 Temperatu...

Страница 6: ...e 100 C The pump will stop immediately after the emergency alarm ring a direct cooling water circuit in the motors in the cylinder covers A and B side of WY rotary lobes vacuum pump and COBRA NS vacuu...

Страница 7: ...safety regulations and must train and instruct his personnel accordingly Local regulations regarding the motors and electric control elements must be observed when installing the pump in potentially...

Страница 8: ...irst then outlet and nitrogen quick connections Put the label or warning board Maintenance processing on or next to the pump SafetyLockout procedure Take off the label or warning board Maintenance pro...

Страница 9: ...to unfavourable ambient condi tions for example aggressive environment frequent temperature changes begin immediately with preservation work on the vacuum pump In the caseof favourable ambient condit...

Страница 10: ...ills the requirements for assembly dismantling Make sure that no temperature sensitive parts for example of plastic wood cardboard paper electronic parts come into contact with the hot surfaces of the...

Страница 11: ...that the regulations of the Electromagnetic Compatibility Directive 2014 30 EU as well as standard EN norms safety directives and especially local and national regulations are observed this is the res...

Страница 12: ...e discharge lines Make sure that all caps safeguards and similar covers are mounted Make sure that the inlet and outlet for the cooling air are not cover ed or closed and that the flow of cooling air...

Страница 13: ...leak within the work area Make sure before every transport using the appropriate lifting mean that the inclination of the vacuum pump is less than 5 CAUTION The vacuum pump must remain in a horizontal...

Страница 14: ...just under cylinder upper plate In casecooling liquid level is belowrequired level Fill in more cooling liquid If the intake line isequipped with a shut off device Open the shut off device If the inta...

Страница 15: ...rectly The cooling water flow is factory set on 10 Nl min and can be adjusted at the regulating cock CWV This water circuit is used to cool the motor of the DP and MB vacuum pumps Make sure that the n...

Страница 16: ...aks repair the vacuum pump Busch Inspect the vacuum pump for leaks of cooling liquid if there are leaks repair the vacuum pump Busch Inspect the vacuum pump for leaks of cooling water if there are lea...

Страница 17: ...densate drain Drain the oil see Draining the oil WY MB rotary lobesvacuumpump If the oil level does not reach the target circle Top up with oil see Refilling oil If the oil level exceeds the target ci...

Страница 18: ...d drain any remaining oil Check that no metal swarf sticks to the magnet of the drain plug clean if necessary Refit the oil drain plugs and tighten up Dispose of the used oil in compliance with applic...

Страница 19: ...f cylinder upper plate Screw on the cooling liquid filler cap again If liquid has run on to the outside surfaces of the vacuum pump wipe it off Draining the cooling liquid Make sure that the vacuum pu...

Страница 20: ...einto pores openings andother internal partsof the vacuumpump There is ahealth hazardwhen dismantling the vacuumpump There is also a danger to the environment Prior to shipping the vacuumpumpmustimper...

Страница 21: ...smantled drain the oil dispose of the oil according to local environmental protection regulations drain the cooling liquid dispose of the cooling liquid according to local environmental protection reg...

Страница 22: ...d to hazardous pumpconditions whichcouldcausepersonalinjury Oil quantity The quantity of oil specified in the following table isof informative nature only Check the oil level with the help of the vari...

Страница 23: ...e glycol and water for the cooling liquid corresponds to a percentage of 40 pure glycol and 60 water It istherefore not necessary to prepare the mix before use But when using pure glycol it isimperati...

Страница 24: ...12 5 10 0 Motor rating DP MB 60 Hz 90 Hz kW 15 15 Nominal motor speed DP 60 Hz min 1 3600 Nominal motor speed MB 90 Hz min 1 5400 Noise level EN ISO 2151 50 Hz 60 Hz dB A dB A 75 Ambient temperature C...

Страница 25: ...lectrical and electronic equipment and following the standards Person authorised to compile the technical file Gerd Rohweder BuschDienste GmbH Schauinslandstr 1 DE 79689 Maulburg Icheon si 07 12 2020...

Страница 26: ...Note...

Страница 27: ...Note...

Страница 28: ...ch Belgium info busch be Hungary busch buschvacuum hu Norway post busch no Taiwan service busch com tw Brazil vendas buschdobrasil com br India sales buschindia com Peru info busch com pe Thailand in...

Отзывы: