![BUSCH COBRA Oxygen NC 0400 B Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/busch/cobra-oxygen-nc-0400-b/cobra-oxygen-nc-0400-b_instruction-manual_2833558021.webp)
Installation | 5
Instruction Manual COBRA NC 0400 B WCV_EN_en
21 | 44
5.6
Fitting the Coupling
1
2
3
4
Description
1
Coupling hub (machine side)
2
Coupling spider
3
Coupling hub (motor side)
4
Set screw; max. admissible torque: 10
Nm
Machine type
Coupling size
Value “E” (mm)
NC 0400 B
ROTEX
®
38
24
ROTEX
®
42
26
In case of a machine delivery without motor:
●
Fit the second coupling hub on the motor shaft (separately delivered).
●
Axially adjust the hub in such a way until value "E" is reached.
●
When the coupling adjustment is done, lock the coupling hub by tightening the radial screw.
●
Mount the motor on the machine by including the coupling spider.
For further coupling information, go to
and download the instruction manual of the
ROTEX
®
coupling.
5.7
Electrical Connection
DANGER
Live wires.
Risk of electrical shock.
●
Electrical installation work must only be executed by qualified personnel.
●
Make sure that the power supply for the motor is compatible with the data on the nameplate of
the motor.
●
The electrical installation must comply with applicable national and international standards.