Installation | 5
0870219588_NS0600C_WCV_Ex_-0000_IM_en
15 / 40
5.2.4 Barrier Gas System Connection
With nitrogen panel
PRV
MV
BGC
MAN
FME, FS
NIP
BGC
Barrier gas connection
FME
Flow meter
FS
Flow switch
MAN
Manometer
MV
Solenoid valve
NIP
Nitrogen panel
PRV
Pressure regulating valve
• Connect the barrier gas connection (BGC) to the gas supply.
Connection size:
– G1/4, ISO 228-1
• Electrically connect the solenoid valve (MV), see Wiring Diagram Solenoid Valve.
• Electrically connect the flow switch (FS) of the flow meter, see
.
• Make sure that the gas complies with the following requirements:
Gas type
Dry nitrogen or air
Gas temperature
°C
0 ... 60
Maximum gas pressure
bar
13
Recommended pressure setting at the
pressure regulating valve (PRV)
bar
3
Filtration
µm
5
Recommended flow rate
SLM*
3,5 ... 5,5
Air quality (only for air)
Acc. to ISO
8573-1
Class 5.4.4.
* standard litre per minute