Maintenance | 7
Instruction Manual COBRA NC 1000 B WCV_EN_en
21 / 32
.
7.3 Cooling Liquid Level Inspection
• Shut down the machine.
MAX
MIN
MAX
MIN
7.4 Replacing the Gas Ballast Filter (Optional)
1
2
3
Discard the part
Busch genuine spare parts
Gas ballast filter: part no. 0562 550 434
7.5 Oil Change
NOTICE
Use of an inappropriate oil.
Risk of premature failure!
Loss of efficiency!
• Only use an oil type which has previously been approved and recommended by
Busch.
Содержание COBRA NC 1000 B
Страница 31: ...Note...