5 | Installation
12 / 32
Instruction Manual COBRA NC 1000 B WCV_EN_en
5.2.4 Barrier Gas System Connection (Optional)
Without nitrogen panel
PRV
FR
BGC
MAN
FME
BGC
Barrier gas connection
FME
Flow meter
FR
Flow regulator
MAN
Manometer
PRV
Pressure regulating valve
• Connect the barrier gas connection (BGC) to the gas supply.
Connection size:
– G1/4, ISO 228-1
• Make sure that the gas complies with the following requirements:
Gas type
Dry nitrogen or air
Gas temperature
°C
0 ... 60
Maximum gas pressure
bar
13
Recommended pressure setting at the
pressure regulating valve (PRV)
bar
3
Filtration
µm
5
Recommended flow rate
SLM*
30
Air quality (only for air)
Acc. to ISO
8573-1
Class 5.4.4.
* standard litre per minute
5.3 Filling Oil
NOTICE
Use of an inappropriate oil.
Risk of premature failure!
Loss of efficiency!
• Only use an oil type which has previously been approved and recommended by
Busch.