8 | Maintenance
28 | 44
Instruction Manual COBRA NX 0950 A WCV_EN_en
CAUTION
Failing to properly maintain the machine.
Risk of injuries!
Risk of premature failure and loss of efficiency!
●
Maintenance work must only be executed by qualified personnel.
●
Respect the maintenance intervals or ask your Busch representative for service.
NOTICE
Using inappropriate cleaners.
Risk of removing safety stickers and protective paint!
●
Do not use incompatible solvents to clean the machine.
●
Shut down the machine and lock against inadvertent start up.
●
Turn off the water supply.
If the machine is equipped with a barrier gas system:
●
Close the barrier gas supply.
●
Vent the connected lines to atmospheric pressure.
If necessary:
●
Drain the cooling water from the two cooling water drain plugs (CWD).
●
Disconnect all connections.
8.1
Maintenance Schedule
The maintenance intervals depend very much on the individual operating conditions. The intervals
given below are considered as starting values which should be shortened or extended as appropri-
ate. Particularly harsh applications or heavy duty operation, such as high dust loads in the environ-
ment or in the process gas, other contamination or ingress of process material, can make it neces-
sary to shorten the maintenance intervals significantly.
Interval
Maintenance work
Monthly
●
Check the oil level, see Oil Level Inspection [
●
Check the machine for oil leaks - in case of leaks have the
machine repaired (contact Busch).
Yearly
●
Carry out a visual inspection and clean the machine from
dust and dirt.
●
Check the electrical connections and the monitoring devic-
es.
●
Clean the inlet screen, see Cleaning the Inlet Screen [
29].
Yearly
In case of those accessories be-
ing installed.
●
Check the filter of the gas ballast valve (GB) and clean it if
necessary, see Cleaning the Gas Ballast Filter (Optional)
[
●
Check the silencer (SI) and clean it if necessary.
●
Check the inlet filter, replace the filter cartridge if neces-
sary.
●
Check and clean the inlet check valve.