Installation | 5
Instruction Manual COBRA NC 0100-0300 B ACV_EN_en
19 | 48
●
Electrically connect the solenoid valve (MV), see Wiring Diagram Solenoid Valve [
24].
●
Electrically connect the two level switches (LS), see Wiring Diagram Level Switch [
●
Fill the flushing liquid vessel (FLV) with a process compatible flushing liquid.
5.6
Fitting the Coupling
NOTE
Radial screw.
For trouble-free operation, use thread locking glue to secure the radial screw.
1
2
3
4
Description
1
Coupling hub (machine side)
2
Coupling spider
3
Coupling hub (motor side)
4
Radial screw / max. admissible torque:
10Nm
Machine type
Coupling size
Value “E” (mm)
NC 0100 B
ROTEX
®
38
24
NC 0200 B
NC 0300 B
NC 0300 B
ROTEX
®
42
26
In case of a machine delivery without motor:
●
Fit the second coupling hub on the motor shaft (separately delivered).
●
Axially adjust the hub in such a way until value "E" is reached.
●
When the coupling adjustment is done, lock the coupling hub by tightening the radial screw.
●
Mount the motor on the machine by including the coupling spider.
For further coupling information, go to www.ktr.com and download the instruction manual of the RO-
TEX
®
coupling.