BUSCH 6224/2.0-WL Скачать руководство пользователя страница 3

 

Information on the manual

 

 

 

 

 

Product manual 2CKA001473B9190 

│3

 

Information on the manual 

Please read this manual carefully and observe the information it contains. This will assist you in 
preventing injuries and damage to property, and ensure both reliable operation and a long 
service life for the device. 

Please keep this manual in a safe place. 

If you pass the device on, also pass on this manual along with it. 

Busch-Jaeger accepts no liability for any failure to observe the instructions in this manual. 

If you require additional information or have questions about the device, please contact Busch-
Jaeger or visit our Internet site at: 

www.busch-jaeger.de/freeathome 

 

 

 

Содержание 6224/2.0-WL

Страница 1: ...Product manual 13 05 2019 Busch free home Room temperature controller wireless 6224 2 0 WL Room temperature controller heating actuator wireless 6224 2 1 WL...

Страница 2: ...awings 11 5 Connection and installation 12 5 1 Planning instructions 12 5 2 Safety instructions 13 5 3 Circuit diagrams 14 5 4 Installation 15 6 Commissioning 17 6 1 Coupling of wireless devices with...

Страница 3: ...ensure both reliable operation and a long service life for the device Please keep this manual in a safe place If you pass the device on also pass on this manual along with it Busch Jaeger accepts no...

Страница 4: ...ning symbol in connection with the signal word Danger indicates an imminently threatening danger which leads to death or serious irreversible injuries Warning Serious damage to health The respective w...

Страница 5: ...deemed contrary to the intended use of the device The associated risk is borne exclusively by the user operator The device is not intended for the following Unauthorized structural changes Repairs Out...

Страница 6: ...Risk of damaging the device due to external factors Moisture and contamination can damage the device Protect the device against humidity dirt and damage during transport storage and operation 2 6 Envi...

Страница 7: ...ntrol of conventional heating and cooling systems The devices are preconfigured and must be parameterised for the use of the functions At initial commissioning the device should not be used for at lea...

Страница 8: ...temperature controller heating actuator wireless 1 1 1 x 3680 W Table 1 Overview of types 3 3 Functions The following table provides an overview of the possible functions and applications of the devi...

Страница 9: ...rview 2 3 4 5 1 Fig 2 Device overview of room temperature controller 1 Phase sensing L 2 Mark TOP 3 Multi point connector for sensor 4 Spring plug in terminal for connecting an external temperature se...

Страница 10: ...e cover and reset optionally removable Transmission protocol free home wireless Transmission frequency 2 400 2 483 GHz Maximum transmission power WL wireless 15 dBm Switching cycles 100 000 Power cons...

Страница 11: ...anual 2CKA001473B9190 11 4 1 Dimensional drawings Notice All dimensions are specified in mm All device types listed in this manual have the same dimensions Fig 4 Dimensions of all described device typ...

Страница 12: ...e home This can be downloaded via Note Transmitter and receiver communicate via radio control The transmission range depends on the structural conditions Walls and ceilings especially steel reinforcem...

Страница 13: ...necessary electrical engineering knowledge and experience Incorrect installation endangers your life and that of the users of the electrical system Incorrect installation can cause serious damage to p...

Страница 14: ...llation Product manual 2CKA001473B9190 14 5 3 Circuit diagrams L N 10 A L N L N 16 A L N 1 A B C C Fig 5 Electrical connection A 6224 2 1 WL B 6224 2 0 WL C Temperature sensor 6226 T optional setting...

Страница 15: ...be pulled off the flush mounted insert before mounting 1 Turn the device into the correct installation position 1 Fig 6 Installation position Notice Observe correct wiring 2 Option Connect the power...

Страница 16: ...uct manual 2CKA001473B9190 16 6 Mount the cover frame Fig 9 Mounting the cover fame 7 Attach the cover with mounted sensor to the flush mounted insert Observe the correct position of the sensor connec...

Страница 17: ...nergized a device that has not been programmed is in programming mode for 30 minutes and can be logged into the system Programmed devices share information about their type and supported functions wit...

Страница 18: ...ireless devices The devices are now in programming mode for 30 minutes Fig 11 Coupling wireless devices with the System Access Point 4 In the user interface of the System Access Point select System se...

Страница 19: ...B9190 19 2 Keep the button at the bottom left pressed 3 Switch the device on again The LED flashes slowly for 10 seconds then fast for 5 seconds and then goes out The factory settings are restored and...

Страница 20: ...given a practical name The allocation is made via the device function of the Web based user interface of the System Access Point 6 2 1 Add device 1 In the Add devices bar select the desired applicati...

Страница 21: ...a the serial number or via switching Identification via serial number Fig 14 Identification via serial number Compare the serial number and the short ID of the identification label which is glued on t...

Страница 22: ...ing only suitable for actuators Fig 15 Identification via switching 1 Select a device and a channel from the list 2 Press the button in the detailed view of the device The connected load is switched 3...

Страница 23: ...r each channel The settings are made via the allocation function of the Web based user interface of the System Access Point Select device Fig 16 Select device 1 Select the device icon 1 in the floor p...

Страница 24: ...to the system the device should not be used for at least 3 hours The heating control switching channel should remain deactivated during this period After this the calibration process starts automatic...

Страница 25: ...ating the room temperature external for regulating Use of an external temperature sensor for reading and regulating the floor temperature For this the external temperature sensor must be laid in the s...

Страница 26: ...tuator and sensor since they are combined in the one device 6 4 1 Linking actuator and sensor Fig 19 Linking actuator and sensor 1 On the working area select the sensor 1 that is to be linked with the...

Страница 27: ...Update Product manual 2CKA001473B9190 27 7 Update A firmware update is carried out via the Web based user interface of the System Access Point...

Страница 28: ...switch ranges is available in the electronic catalogue www busch jaeger catalogue com Fig 20 Operation 1 ECO mode press the button 2 Increase in temperature reduction press the button 3 Temperature O...

Страница 29: ...ECO mode Off mode Application The room is not being used for a longer period of time Behaviour of the RTC The display shows OFF The heating valves are closed frost protection is active Table 6 OFF mod...

Страница 30: ...s 1 Controller On display of set point temperature 2 Controller Off 3 Heating active 4 Cooling active 5 Frost protection mode active 6 Eco mode display ECO 7 Display of comfort mode heating 8 Display...

Страница 31: ...tion maintenance and repairs according to DIN VDE 0100 520 9 1 Cleaning Caution Risk of damaging the device When spraying on cleaning agents these can enter the device through crevices Do not spray cl...

Страница 32: ...Notes Product manual 2CKA001473B9190 32 10 Notes...

Страница 33: ...al 3 Installation 15 Intended use 5 L Liability 3 Links 26 actuator 26 sensor 26 M Maintenance 31 Messages 30 N Notes 32 O Operation 28 Overview of types 8 P Parameter settings of room temperature con...

Страница 34: ...oup PO box 58505 L denscheid Freisenbergstra e 2 58513 L denscheid www BUSCH JAEGER de info bje de abb com Central sales service Tel 49 2351 956 1600 Fax 49 2351 956 1700 Copyright 2019 Busch Jaeger E...

Отзывы: