Pump Control Instructions

R5 / COBRA

with Variable-Frequency Drive
R5 RA/RC 0630 B/C
COBRA NC 0630 C / NX 0650 A / NX 0950 A

0870208958/-0002_en / Original instructions / Modifications reserved

15/02/2021

Ateliers Busch S.A.
Zone industrielle, 2906 Chevenez
Switzerland

Содержание 0987 209 539

Страница 1: ...mp Control Instructions R5 COBRA with Variable Frequency Drive R5 RA RC 0630 B C COBRA NC 0630 C NX 0650 A NX 0950 A 0870208958 0002_en Original instructions Modifications reserved 15 02 2021 Ateliers...

Страница 2: ...ters Set Change Values 22 7 3 1 Description 22 7 3 2 How to know if the machine has two set values 22 7 3 3 Parameters not to be changed 22 7 4 Start Stop Functionality 23 7 4 1 Description 23 7 4 2 P...

Страница 3: ...has been designed and manufactured according to state of the art meth ods Nevertheless residual risks may remain This instruction manual highlights potential haz ards where appropriate Safety notes a...

Страница 4: ...nstructions This document is delivered along with variable frequency drive control device It only contains information about the variable frequency drive parametrisation and con trol Please refer to t...

Страница 5: ...729 2 Cable for PC 1 0987 208 730 3 USB Stick including PC Software para meter list factory settings pump con trol instructions 1 0889 209 540 3 2 Application The parameter kit is intended for Parame...

Страница 6: ...e Risk of damage to the variable frequency drive The remote control must only be operated with INVEOR variable frequency drive M12 interface socket Connect the cable of the remote control to the M12 i...

Страница 7: ...s With these buttons the motor is started or stopped Commands Procedures Next Calling up parameters and submenu Back One menu level higher Cancel End entry without saving Change Call up edit mode curs...

Страница 8: ...ode 9 Contains advanced parameters for special uses the expert mode is activated in the main menu The remote control always starts in standard mode x x The INVEOR MMI always starts in standard mode If...

Страница 9: ...View of main menu Fig 8 View of parameter group expert mode Part 1 01 Actual values Basic parameter Control mode Process controller Low speed High speed Deceleration 1 Acceleration 1 Deceleration 2 Ac...

Страница 10: ...ut AI2 max input AI2 dead time AI2 filter time AI2 function AI2 phy unit AO1 function AO1 min output AI1 max input DO1 function DO1 on DO1 off DO2 function DO1 on DO1 off Relay1 function Relay1 on Rel...

Страница 11: ...e Process data out 3 Process data out 10 Process data in 3 Processdata in 6 Motor type i2t fac mot I2T time Opt stat resist Motor current Motor power Motor speed Motor frequency Motor resistance Leaka...

Страница 12: ...ts stops of the machine Use the digital start signal The machine will run at the following fixed speed factory settings Machine type Motor frequency R5 RA RC 0630 B 60 Hz R5 RA RC 0630 C 60 Hz COBRA N...

Страница 13: ...o commencing any work DANGER Carry out any work on the variable frequency drive and motor Risk of electrical shock Electrical installation work must only be executed by qualified personnel NOTICE Chan...

Страница 14: ...e the Machine Make sure that the variable frequency drive is de energised Remove the bridge between 24V Out int power supply and En HW enable hardware in order to avoid any start up Energise the varia...

Страница 15: ...nt parameters via PC Software Make sure that the machine is disabled see Disable the Machine 14 Connect the variable frequency drive to the computer with the provided cable Start the PC Software previ...

Страница 16: ...l or specific para meters for future purposes NOTE Custom parametrisation via the remote control Please keep a note of each changed parameters As soon as the parametrisation is finished De energise th...

Страница 17: ...bled see Disable the Machine 14 Connect the variable frequency drive to the computer with the provided cable Start the PC Software previously installed see PC Software Installation 6 Select Open to lo...

Страница 18: ...ram downloading Check the motor parameters match to the motor fitted on the machine As soon as the parametrisation file is loaded De energise the variable frequency drive Reconnect the variable freque...

Страница 19: ...ange only the allowed parameters described in the chapter Parameter Description 19 NOTICE Changing of any other parameters than described below Risk of damage to the machine Do not change any other pa...

Страница 20: ...s 1 2 1 changeover contact NO NC Maximum switching power at ohmic load cos 1 5 A at 230 V or 30 V at inductive load cos 0 4 and L R 7 ms 2 A at 230 V or 30 V Maximum reaction time 7 ms 0 5 ms Electric...

Страница 21: ...ircuit elements such as protector switches and brake coils or circuit elements that are operated via the outputs of the drive controller have to be interference sup pressed RC circuits are suitable as...

Страница 22: ...ration 7 3 2 How to know if the machine has two set values If Value 1 and Value 2 are shown in the parameters when opening the parameters list in the software your machine therefore has two set values...

Страница 23: ...response to enabling software parameter 1 131 0 immediate start with high signal at input of control enable 1 start only with rising edge at input of control enable 2 digital input 1 function active...

Страница 24: ...speed This parameter cannot be changed risk of damage on the machine 7 5 3 Speed Control 3 Fixed Frequency Min Frequency In this configuration if the Digital Input 1 and Digital Input 2 are permanent...

Страница 25: ...the operation mode following software enabling 1 131 and hardware en abling the drive controller runs as follows 2 fixed frequencies with the frequencies defined in parameters 2 051 and Minimum freque...

Страница 26: ...acteristics Analogue inputs 1 2 In 10 V or 0 20 mA In 2 10 V or 4 20 mA 10 bit resolution Tolerance 2 Voltage input Rin 10 kOhm Current input Working resistance 500 Ohm 7 6 2 Speed Control via Interna...

Страница 27: ...m value of the analogue inputs as a percentage of the range Example 0 10 V 0 100 2 10 V 20 100 100 10 V 100 default value to be adapt to your process 4 023 AI1 dead time Dead time as percentage of the...

Страница 28: ...rce from which the target value is to be read 1 analogue input 1 4 020 AI1 input type Function of analogue input 1 2 current input 4 021 AI1 standard Low Specifies the minimum value of the analogue in...

Страница 29: ...d Control via Analogue Input 2 7 6 4 1 Voltage Input 1 100 Operating mode Selecting the operation mode following software enabling 1 131 and hardware en abling the drive controller runs as follows 0 f...

Страница 30: ...3 0 4 063 1 bar 4 063 2 mbar 4 063 3 psi 4 063 4 Pa 4 063 5 m3 h 4 063 6 l min 4 063 7 C 4 063 8 F 4 063 9 m 4 063 10 mm 4 064 AI2 physical minimum Selection of the lower limit of a physical value to...

Страница 31: ...to be adapt to your process 4 053 AI2 dead time Dead time as percentage of the range of the analogue input 0 no dead time default value to be adapted to your process 4 054 AI2 filter time second Filt...

Страница 32: ...l value Depending on the control difference a rotation speed value is output to the control out put with the help of the amplification factors for the proportional gain 3 050 integral gain 3 051 and d...

Страница 33: ...hare of PID controller amplification factor 0 5 should be adapt to your application depending on the pump capacity and cus tomer installation 3 0502 PID D amplification factor Differential share of PI...

Страница 34: ...ersely The internal actual value then corresponds to 100 70 30 In other words the target value to be specified is 30 3 069 PID fixed target mode Selection of the digital inputs used for fixed frequenc...

Страница 35: ...ing a waiting time the PID stand by time 3 070 with the minimum frequency 1 020 Once the actual value deviates from the target value by the set value the PID stand by hysteresis 3 071 the control the...

Страница 36: ...on the variable frequency drive and motor Risk of electrical shock Electrical installation work must only be executed by qualified personnel NOTICE Variable frequency drive maintenance Risk of damage...

Страница 37: ...ows the errors to be diagnosed The following table contains an overview Red LED Green LED State Boot loader active flashing in turn Ready for operation activate En_HW for operation Operation ready War...

Страница 38: ...EMC interference 10 Parameter distributor The internal distribution of parameters during initialisation failed Parameter set is incomplete 11 Time out power The power part does not respond Operation...

Страница 39: ...s motor temperature Motor PTC has been triggered Overload of the motor e g high torque at low motor speed ambient temperature too high 36 Power failure The grid voltage has dropped briefly Grid fluctu...

Страница 40: ...ble causes remedy 49 Power class restriction Max overload of the variable fre quency drive exceeded for more than 60 sec Check application reduce load use larger variable frequency drive 53 Motor tipp...

Страница 41: ...Note...

Страница 42: ...Note...

Страница 43: ...Note...

Страница 44: ...Japan info busch co jp Korea busch busch co kr Malaysia busch busch com my Mexico info busch com mx Netherlands info busch nl New Zealand sales busch co nz Norway post busch no Peru info busch com pe...

Отзывы: