background image

Commissioning

Product manual 2TMD042200D0021

38

 (1)

 Set the door lock time

If the default lock type is set to "IP actuator", follow the steps below,

Содержание 2TMA130010A0003

Страница 1: ...2TMD042200D0021 22 06 2022 Product manual Busch Welcome IP H8131 P 03 Mini video outdoor station H8136 P 03 Mini video outdoor station ...

Страница 2: ...on 16 7 2 6 Cavity wall installation 17 7 2 7 Replacing the nameplate 18 8 Commissioning 19 8 1 Configure the settings on indoor station 19 8 1 1 Outdoor station enters engineering mode 19 8 1 2 Indoor station enters engineering settings 20 8 1 3 Local device settings 21 8 1 4 Lock management 23 8 1 5 Door status detection 24 8 1 6 Sound setting 25 8 1 7 Anti flicker setting 26 8 1 8 Set the funct...

Страница 3: ...s Product manual 2TMD042200D0021 3 9 Cyber security 45 9 1 Disclaimer 45 9 2 Performance and service 45 9 3 Deployment guideline 46 9 4 Upgrading 46 9 5 Backup Restore 46 9 6 Malware prevention solution 46 10 Notice 47 ...

Страница 4: ...ass on this manual along with it Busch Jaeger accepts no liability for any failure to observe the instructions in this manual 2 Safety Warning Electric voltage Dangerous currents flow through the body when coming into direct or indirect contact with live components This can result in electric shock burns or even death Disconnect the mains power supply prior to installation and or disassembly Permi...

Страница 5: ...eger devices All packaging materials and devices from Busch Jaeger bear the markings and test seals for proper disposal Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company Busch Jaeger products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance...

Страница 6: ...uminum alloy 99 x 168 x 26 H81313P2 A 03 2TMA130010A0006 Mini video outdoor station 2 buttons ID SM Aluminum alloy 99 x 168 x 26 H81363P1 A 03 2TMA130010A0009 Mini video outdoor station 1 button ID FM Aluminum alloy 105 x 180 x 43 H81363P2 A 03 2TMA130010A0012 Mini video outdoor station 2 buttons ID FM Aluminum alloy 105 x 180 x 43 H81364P1 A 03 2TMA130010A0015 Mini video outdoor station 1 button ...

Страница 7: ...nual 2TMD042200D0021 7 5 2 Control elements No Description 1 Indicator flashes slowly ringing Indicator flashes quickly busy line 2 Call indicator 3 Unlock indicator 4 Speaker and microphone integration 5 Round pushbutton 4 5 1 2 3 ...

Страница 8: ... Connector for the sensor used for door status detection 2 Connector for exit button 3 Plug in clamps LOCK AGND for door opener 4 Plug in clamps COM NC NO for floating output 5 Plug in clamps DC GND for standalone power supply 6 LAN PoE 7 N A DS NC COM NO GND DC LAN 1 2 3 4 5 6 7 LOCK AGND EXIT ...

Страница 9: ... to open 12 V Type A B Electrical strike lock 24V Power on to open 24 V Type B Electrical rim lock 12 V Power on to open 12 V Type A B Electrical mortise lock Power off to open 12 V Type C Magnetic lock Power off to open 12 24 V Type C AGND GND NO DC NC DS LOCK COM EXIT AGND GND NO DC NC DS LOCK COM EXIT AGND GND NO DC NC DS LOCK COM EXIT PS PS Type A Type B Type C ...

Страница 10: ... 24 V 350 mA Operating temperature 40 C 55 C Product dimensions 99 mm x 168 mm 26 mm H8131 P 105 mm x 180 mm 43 mm H8136 P Camera type CMOS Camera viewing angle 104 Power supply for door opener 15 V 4A impulse max 250 mA holding Floating output for door opener 30 V 3 A IP level IP 54 IK level IK 07 Network connection standard IEEE802 3 10 100 Mbps auto MDI MDI X ...

Страница 11: ...edge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect 2 Secure against being re connected 3 Ensure there is no vol...

Страница 12: ...Mounting Installation Product manual 2TMD042200D0021 12 7 2 Mounting 7 2 1 Preparation Use gloves to protect yourself against cuts 7 2 2 Installation height 1 5 m 5 feet ...

Страница 13: ... 7 2 3 Installation situation Note The following installation situations must be avoided without fail to ensure picture quality Direct light Direct sunlight Extremely bright picture background Highly reflective walls on the opposite side of the door station ...

Страница 14: ...duct manual 2TMD042200D0021 14 7 2 4 Surface mounted installation Product dimension Surface mounted on the wall 99 mm 26 5 mm 78 mm 62 mm 62 mm 83 mm 60 mm 168 mm 147 mm 3 2 1 Screw shaft 4 Screw length 25 mm Mounting screw x 4 ...

Страница 15: ...Mounting Installation Product manual 2TMD042200D0021 15 Surface mounted on the box e g VDE box 3 2 1 Screw shaft 4 Screw length 25 mm Mounting screw x 4 ...

Страница 16: ...ct manual 2TMD042200D0021 16 7 2 5 Flush mounted installation Product dimension Flush mounted with pre installation box 105 mm 180 mm 53 mm 174 mm 99 mm 45 mm 99 mm 174 mm 3 2 1 Screw shaft 4 Screw length 25 mm Mounting screw x 4 ...

Страница 17: ...ation Product manual 2TMD042200D0021 17 7 2 6 Cavity wall installation Product dimension Mounting 105 mm 180 mm 43 mm 90 mm 168 mm 92 mm 97 mm 120 mm 170 mm Screw shaft 4 Screw length 25 mm Mounting screw x 4 1 2 3 4 5 ...

Страница 18: ...Mounting Installation Product manual 2TMD042200D0021 18 7 2 7 Replacing the nameplate 3 4 6 5 1 2 2 ...

Страница 19: ...e network as the indoor station Please follow the steps below Power up the mini outdoor station the three indicators light up green After a period of time the three indicators go out Hold the first pushbutton for 5 s When the pushbutton module and the three indicators are flashing green at the same time the mini outdoor station enters engineering mode Pushbutton module First pushbutton Unlock indi...

Страница 20: ...ers engineering settings On the extra screen of indoor station click System to access the corresponding screen On the System settings screen click Engineering settings enter the engineering password and then click Outdoor station settings to access the corresponding screen ...

Страница 21: ...oduct manual 2TMD042200D0021 21 8 1 3 Local device settings On the Outdoor station settings screen select the device type 2nd OS 1 Location Internal With this setting 2nd OS is connected to the router in the apartment ...

Страница 22: ...oduct manual 2TMD042200D0021 22 2 Location External With this setting 2nd OS is connected to the switch outside the apartment Note The external and internal types cannot be used in mixed scenarios in the same apartment ...

Страница 23: ...reen No Function 1 Unlock type when swiping Set the lock to be released when swiping Default lock default Subsidiary lock 2 Lock type Set the lock type for the default lock and subsidiary lock Lock GND NO NC COM IP actuator 3 Time of unlock Set the time for unlock Power lock Lock GND Signal lock NO NC COM ...

Страница 24: ...n If this function is enabled the outdoor station will send an alarm to the management software if the door is open longer than 120 s a sensor should first be connected to the outdoor station 2 Tamper proof alarm If this function is enabled the outdoor station will send an alarm to the management software if the outdoor station is removed from the wall ...

Страница 25: ...ume of outdoor station Click or to adjust the ringtone volume and the voice volume on the outdoor station 2 Button tone Tick the checkbox to enable button tones on the outdoor station 3 Voice prompt Tick the checkbox to enable voice prompts on the outdoor station Choose the language for the voice prompts from the drop down list ...

Страница 26: ...Commissioning Product manual 2TMD042200D0021 26 8 1 7 Anti flicker setting On the Outdoor station settings screen select the refresh rate from the drop down list ...

Страница 27: ...MD042200D0021 27 8 1 8 Set the function of pushbutton On the Outdoor station settings screen click Push button address setting to access the settings of the pushbuttons Note Device no should be entered if Phone guard unit is selected ...

Страница 28: ...0021 28 8 1 9 Time sync setting On the Outdoor station settings screen If Sync with mgmtc is selected the outdoor station will sync the time from the management software If Close time sync is selected the time and date need to be set manually ...

Страница 29: ...Commissioning Product manual 2TMD042200D0021 29 8 1 10 Compatible mode setting On the Outdoor station settings screen the outdoor station is set to Security mode by default Compatible mode off ...

Страница 30: ...the firmware Note The outdoor station doesn t need to enter engineering mode when you want to upgrade the firmware On the Outdoor station settings screen click Firmware update select the outdoor station and the file from SD card then click OK to update the firmware ...

Страница 31: ...Commissioning Product manual 2TMD042200D0021 31 8 1 12 Viewing the version On the Outdoor station settings screen view the version information ...

Страница 32: ...Commissioning Product manual 2TMD042200D0021 32 8 1 13 Serial number On the Outdoor station settings screen view the serial number this number is used to get the signature from the management software ...

Страница 33: ...Commissioning Product manual 2TMD042200D0021 33 8 1 14 Signature On the Outdoor station settings screen view the signature ...

Страница 34: ...e can be added by SmartAP This mini outdoor station will lose its certificate if its physical address is changed The mini outdoor station needs to be powered on before being added On the Smart Access Point configuration screen follow the steps below Note If the mini outdoor station is installed in the community network Installed in the coummunity network should be enabled ...

Страница 35: ...Commissioning Product manual 2TMD042200D0021 35 8 2 2 Configure the settings On the configuration screen click Door entry system Outdoor stations then click a mini outdoor station to access the settings ...

Страница 36: ...on 1 Device ID 2 Click the icon to return to the previous screen 3 Overview of the outdoor station 4 Device type of the outdoor station 5 Display the address of the outdoor station 6 Display the serial number of the outdoor station 7 Display the version of the outdoor station ...

Страница 37: ...address for the outdoor station 2 1 Set the unlock time for default lock and subsidiary lock 3 Enable or disable the time synchronization with the management software 4 Update the firmware via local PC 5 Update the firmware via the external website 6 2 Set the trusted devices for the outdoor station ...

Страница 38: ...Commissioning Product manual 2TMD042200D0021 38 1 Set the door lock time If the default lock type is set to IP actuator follow the steps below ...

Страница 39: ...Commissioning Product manual 2TMD042200D0021 39 On the designated IP actuator screen follow the steps below ...

Страница 40: ...Commissioning Product manual 2TMD042200D0021 40 ...

Страница 41: ...0021 41 2 Set the trusted devices On the designated mini outdoor station screen follow the steps below Note You need to enable the Trust this management software function if you want this outdoor station to unlock in the event of an emergency ...

Страница 42: ...eate admin card Swipe card 1x Green Enter settings Swipe admin card 1x Orange After entering settings following functionalities can be implemented Function Action Unlock indicator Enrol user Swipe admin card 1x Orange flashes 1x Swipe user card 1x Green Delete user Swipe admin card 2x Orange flashes 2x Swipe user card 1x Green Enrol new admin Swipe admin card 3x Orange flashes 3x Swipe new admin c...

Страница 43: ...ed within 15 seconds Function Action Unlock indicator Open a door Swipe the enrolled keycard Green Technical data of ID card Work frequency Standard 125KHz EM4100 EM4205 EM4305 EM4450 TK4100 T5567 T5577 Note A maximum of 64 ID cards can be supported by mini outdoor station 2 Card management on management software Please see the Management software product manual for more details ...

Страница 44: ...l turn off 2 Then press and hold the 1st button for 3 seconds within 30 seconds until 3 LED indicators begin to flash green at the same time to indicate the device enters configuration mode 3 Press and hold the 1st button for 10 seconds until 3 LED indicators turn off 4 The device will reboot automatically and unlock indicator will flash red green and orange repeatedly ...

Страница 45: ...es related to such security breaches unauthorized access interference intrusion leakage and or theft of data or information Although Busch Jaeger provides functionality testing on the products and updates that we release you should institute your own testing program for any product updates or other major system updates to include but not limited to code changes configuration file changes third par...

Страница 46: ...ide to remove the device from system user shall reset the device to factory setting in order to remove all the configuration data and sensitive data in the device This will prevent sensitive data leak It is recommended to apply MAC filter and Rate limiter in the switch to prevent DOS attack 9 4 Upgrading Device supports firmware updates via management software a signature file will be used to veri...

Страница 47: ...ications agreed to at the time of ordering apply to all orders Busch Jaeger accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or excerpts thereof must not be reproduced transmitted or reused by third parties without prior written consent by Busch Ja...

Страница 48: ... of the ABB Group Freisenbergstraße 2 58513 Lüdenscheid www BUSCH JAEGER de info bje de abb com Central sales service Tel 49 2351 956 1600 Fax 49 2351 956 1700 Copyright 2022 Busch Jaeger Elektro GmbH All rights reserved 2TMD042200D0021 ...