Device Functions
System Manual 2CKA001473B9426
│22
Seated: maximum detection range diameter
Bu
s syst
em
Control
Mounti
n
g
he
ight 2
.5
m
Mounti
n
g
he
ight 3
.0
m
6817/62-xxx
Compact, e-contact
Ø max. 5 m
Ø max. 6.5 m
6817/32-xxx
Universal, e-contact
Ø max. 8 m
Ø max. 10 m
6819/60-xxx
Compact, Relais
Ø max. 5 m
Ø max. 6.5 m
6819/30-xxx
Universal, Relais
Ø max. 8 m
Ø max. 10 m
6819/50-xxx
Corridor, Relais
—
(1
—
(1
6817/33-xxx
Universal BT, e-contact
Ø max. 8 m
Ø max. 10 m
6817/93-xxx
Universal BT, e-contact
with sealing ring
Ø max. 8 m
Ø max. 10 m
6819/31-xxx
Universal BT, Relais
Ø max. 8 m
Ø max. 10 m
6819/51-xxx
Corridor BT, Relais
—
(1
—
(1
6819/38-xxx
Universal, Slave
Slave
Ø max. 8 m
Ø max. 10 m
6819/68-xxx
Compact, Slave
Ø max. 5 m
Ø max. 6.5 m
6819/58-xxx
Corridor, Slave
—
(1
—
(1
6819/35-xxx
Universal BT, DALI
DALI
Ø max. 8 m
Ø max. 10 m
6819/55-xxx
Corridor BT, DALI
—
(1
—
(1
6819/39-xxx
Universal, DALI Slave
Slave
Ø max. 8 m
Ø max. 10 m
6819/59-xxx
Corridor, DALI Slave
—
(1
—
(1
Table 7: Overview of the detection ranges seated
1)
Not recommended for seated applications.