Operating Instructions
Busch-Wächter
®
Operation
Operating Instructions | 1473-1-8108
— 7 —
4.1 Display
area
Fig. 2:
Display area
No. Function
1
In this area the ON period of the lighting and the short-time pulse are set.
2
In this area the brightness limit value is set.
Switching during darkness (0.2 lux)
Switching during twilight (3 lux)
Switching during twilight (6/7 lux)
Switching during twilight (15/20 lux)
Daytime operation (>350 lux)
3
In this area the sensitivity of the movement detector is set.
- A reduced sensitivity is necessary in a disturbed environment (trees / bushes in the detection range) or
excessively long ranges.
4
In this area additional functions are switched on and off.
- Dynamic forced switch-off
Only for 220 MasterLINE premium
– Separation of detection zones 1 and 2
- Synchronous operation of relays 1 and 2
- Twilight switch operation relay 2
5
Display of transmission LED
1
2
3
4
Empfindlichkeit
Zeit
10 Sek
1 Min
5 Min
3 Min
5
Zonen
Synchron