GB
140
6.6.2 Dusk function
The operating element compares the ACTUAL value with
the SETPOINT value; a (DOWN) motion command is actu-
ated
until the blinds are fully down
as soon as the
ACTUAL value falls below the SETPOINT value and an
internal delay time has elapsed.
The values are allocated as follows:
- value from 1– 9:
15 to 300 lux
- "OFF"
no dusk function
If the set dusk value is fallen short of, the symbol
blinks
in the display.
NOTE
The dusk function is normally inactivated from 00:00 hrs. to
15:00 hrs., i.e., the blind cannot close in the morning in
accordance with the dusk function.
The blind can only be closed via the dusk function in the
evening. The blind can only be opened in the morning
manually or via a programmed switching command.
Programming