background image

 

 

 

 
 

2CKA001473B8291  

│  

05.07.2018 

Product manual 

Electronic room temperature controller insert 

1098 U-101 

1098 UF-101

 

 

 

 

 

 

 

 

 

 

 

Содержание 1098 U-101

Страница 1: ...2CKA001473B8291 05 07 2018 Product manual Electronic room temperature controller insert 1098 U 101 1098 UF 101 ...

Страница 2: ...cal data 11 6 Connection installation mounting 12 6 1 Requirements for the electrician 12 6 2 Mounting dismantling 13 6 3 Electrical connection 15 7 Commissioning 16 8 Operation 17 8 1 Notes on operation 17 8 2 Operating modes 18 8 3 Normal operation 19 8 3 1 Display 19 8 3 2 Button assignment 20 8 4 Device settings 21 8 4 1 Menu tree 22 8 4 2 Language 24 8 4 3 RESET Resetting the device 25 8 4 4 ...

Страница 3: ...Table of contents Product manual 2CKA001473B8291 3 8 6 7 Adjust temperature 37 8 7 Display during mains power failure 39 9 Maintenance 40 9 1 Cleaning 40 10 Index 41 ...

Страница 4: ...e to property and ensure both reliable operation and a long service life for the device Please keep this manual in a safe place If you pass the device on also pass on this manual along with it Busch Jaeger accepts no liability for any failure to observe the instructions in this manual If you require additional information or have questions about the device please contact Busch Jaeger or visit our ...

Страница 5: ... the signal word Danger indicates an imminently threatening danger which leads to death or serious irreversible injuries Warning Serious damage to health The respective warning symbol in connection with the signal word Warning indicates a threatening danger which can lead to death or serious irreversible injuries Caution Damage to health The respective warning symbol in connection with the signal ...

Страница 6: ...suitable surface mounted housings Use with the connecting options available on the device The intended use also includes adherence to all specifications in this manual 2 3 Improper use Each use not listed in Chapter 2 2 Intended use on page 6 is deemed improper use and can lead to personal injury and damage to property Busch Jaeger is not liable for damages caused by use deemed contrary to the int...

Страница 7: ...The electrical installer must have read and understood the manual and follow the instructions provided The electrical installer must adhere to the valid national regulations in his her country governing the installation functional test repair and maintenance of electrical products The electrical installer must be familiar with and correctly apply the five safety rules DIN VDE 0105 EN 50110 1 Disco...

Страница 8: ... qualified electricians Disconnect the mains power supply before installation disassembly Never use the device with damaged connecting cables Do not open covers firmly bolted to the housing of the device Use the device only in a technically faultless state Do not make changes to or perform repairs on the device on its components or its accessories Keep the device away from water and wet surroundin...

Страница 9: ...e of the device at the appropriate collecting depot All packaging materials and devices bear the markings and test seals for proper disposal Always dispose of the packaging material and electric devices and their components via the authorized collecting depots and disposal companies The products meet the legal requirements in particular the laws governing electronic and electrical devices and the ...

Страница 10: ... 4 1 Features of function and equipment 4 1 1 Control elements The following modules are used The device can only be operated with central cover plate 6435 xxx The cover plate is latched onto the control element as a so called floating rocker 1098 U 101 1098 UF 101 6435 xxx ...

Страница 11: ...ion 1 16 2 A Change over contact normally closed contact open while de energized connection 2 5 2 A Control range 1098 U 101 5 C 30 C 1098 UF 101 10 C 50 C Opening of change over contact 3 mm µ Power reserve Approx 10 h at 25 C Memory locations Maximum of 28 switching times Shortest switching interval 5 minutes Ambient temperature 0 C 30 C Protection type IP 20 Regulation EN 60 730 2 9 Input 1098 ...

Страница 12: ...our life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect 2 Secure against being re connected 3 Ensure there is no voltage 4 Connect to earth and short circuit 5 Cover or b...

Страница 13: ...device are sensitive Pull the attachment off only with your hands Do not lever parts off with screwdrivers or similar hard objects In Germany the flush mounted insert must only be installed in flush mounted boxes according to DIN 49073 1 Part 1 or suitable surface mounted housings Different installation standards apply in other countries These are to be taken into account when used in connection w...

Страница 14: ...your hands Do not lever parts off with screwdrivers or similar hard objects This will damage the device When pulling off first the resistance of the plastic clamps must be overcome Fig 2 Device in as delivered state pulling off the attachment 1 Connect the cables to the flush mounted insert For the connection assignment see chapter see chapter 6 3 Electrical connection on page 15 Fig 3 Connecting ...

Страница 15: ...2 1 L N L N 2 1 16A 16A 1098 UF 101 1098 U 101 Fig 4 Circuit diagrams Terminal designation Assignment L Phase N Neutral conductor 1 Output for controlling the heating load 2 Output for controlling the cooling load ϑ Remote sensor connections The sensor cable must be installed in a protective cable duct ...

Страница 16: ...Commissioning Product manual 2CKA001473B8291 16 7 Commissioning Notice The setup is carried out automatically during initial commissioning or when resetting the settings RESET ...

Страница 17: ...data remain saved The operating element can be removed from the flush mounting insert for approximately 20 minutes and adjusted separately A total of 4 switching times per day can be set 2 x for comfort mode 1 x for standby mode 1 x for night mode If the display is on this can mean the following No time has been set The memory is not occupied The function is not active Flashing numbers values can ...

Страница 18: ...is present This function is not automatically activated at the factory NIGHT MODE Temperature during the night OFF The control system is switched off No temperature value is displayed The display appears when OFF is activated Manual temperature changes are not possible The temperature can be changed manually at all times Press the OK button for 2 seconds to change the operating mode All of the tem...

Страница 19: ... 1 Display of programmed daily cycles 2 Info line time date 3 Icon for C 4 Mains power failure 5 Status display heating 6 Current weekday 7 Automatic operating mode 8 Comfort Standby operating mode 9 Night operating mode 10 Temperature status Notice If the text is too long for the info line it will run through the info line ...

Страница 20: ... mode Press all buttons of the rocker switch simultaneously for approx 5 seconds The temperature controller will be reset to the factory settings Raise temperature Select menu items Adjust values Lower temperature Confirmation Select menu Accept value Notice The set temperature will be adjusted regardless of the time programs If necessary the value can be manually adjusted with the UP button or DO...

Страница 21: ...essed for 5 seconds to release the button lock The button lock can also be deactivated See see chapter 8 6 5 Button lock on page 34 Commissioning must be carried out anew after a reset After initial commissioning or after a reset the device briefly displays the version number A detailed description of the individual operating steps for programming is contained in the following sub sections Notice ...

Страница 22: ...mode Setting the starting times for switching the temperature regulation on and off independent from each other for each weekday Night mode Comfort mode Night mode Special functions Max and min values Max setting value Setting maximum and minimum temperatures Min setting value Valve protection On Off Switching the service circuit on or off for automatic opening of the heating valves Standby times ...

Страница 23: ...Operation Product manual 2CKA001473B8291 23 Standby mode 30 0 C Night mode 25 0 C ...

Страница 24: ...rmany Select language Select the country via the arrow buttons Confirm your selection with the OK button You simultaneously switch to the next menu item This is followed by setting the year month day hour and minute See Chapter 8 6 6 Date Time on page 35 Notice To change the language at a later point in time see Chapter 8 4 4 RESET resetting to the factory settings on page 25 ...

Страница 25: ...ry settings Comfort mode Mon Fri 07 00 h Sat Sun 08 00 h 23 C 23 C Standby mode Mon Sun 09 00 h Can be selected if required special functions menu 19 C Night mode Mon Sun 22 00 h 16 C 1 Press all 4 buttons simultaneously or the entire operating surface for more than 5 seconds For this the device must be in operating mode The text Factory settings will appear in the display 2 Confirm the enquiry wi...

Страница 26: ...e programmed on the same day BLOCK programming So that the switching times need not be entered again for each individual day the BLOCK programming function is available This means that the switching times are entered once for block Mon Fri and once more for block Sat Sun DAY programming Here the switching times for each day can be set independent from each other The settings that are available and...

Страница 27: ...t menu item Night mode Mon Fri The preset starting time flashes 22 30 Set the desired starting time via the arrow buttons In this example the starting time has been set at 22 30 Comfort mode 08 00 Press the OK button again You simultaneously switch to the next menu item Comfort mode Sat Sun The preset starting time flashes 8 30 Set the desired switch on time via the arrow buttons In this example t...

Страница 28: ...Operation Product manual 2CKA001473B8291 28 Press the menu button to switch to the operating mode Table 1 Sequence of operating steps ...

Страница 29: ...al functions Select menu Special functions via the arrow buttons Max and min values Press the OK button to select menu item Max and Min values Max setting value 50 0 Confirm your entry with the OK button Menu item Max setting value is called up The preset maximum temperature of 50 C flashes 45 0 Set the desired temperature via the arrow buttons The values can be set in steps of 0 5 C The adjustmen...

Страница 30: ...ttons In this example a temperature of 20 C has been set Max and Min values Confirm your entry with the OK button The maximum and minimum temperature values have been set Special functions Press the menu button to switch to menu level Special functions Press the menu button to switch to the operating mode Table 2 Sequence of operating steps ...

Страница 31: ... Press the menu button for 2 seconds to switch to the setting mode Special functions Select menu Special functions via the arrow buttons Valve protection Press the OK button to select menu item Valve protection The default setting flashes On Off Set the service circuit to ON or OFF via the arrow buttons On Confirm your entry with the OK button In the example the setting On has been selected Specia...

Страница 32: ...econds to switch to the setting mode Special functions Select menu Special functions via the arrow buttons Standby Press the OK button to select menu item Standby times The default setting flashes On Off Set the standby times to ON or OFF via the arrow buttons On Confirm your entry with the OK button In the example the setting On has been selected Special functions Press the menu button to switch ...

Страница 33: ...cial functions Select menu Special functions via the arrow buttons OFFSET Press the OK button to select menu item OFFSET The preset value flashes 0 0 Adjust the temperature Set the temperature variance to the measured temperature on site via the arrow buttons The value can be set in steps of 0 1 C 0 8 Confirm your entry with the OK button In this example an OFFSET value of 0 8 C has been entered S...

Страница 34: ...onds to switch to the setting mode Special functions Select menu Special functions via the arrow buttons Button lock Press the OK button to select menu item Button lock The default setting flashes On Off Set the button lock to ON or OFF via the arrow buttons On Confirm your entry with the OK button In the example the setting On has been selected The button lock has been activated Special functions...

Страница 35: ...y with the OK button You simultaneously switch to the next menu item Month The preset month flashes 6 01 Set the month via the arrow buttons Day Confirm your entry with the OK button You simultaneously switch to the next menu item Day The preset day flashes 6 01 Set the day via the arrow buttons Hour Confirm your entry with the OK button You simultaneously switch to the next menu item Hour The pre...

Страница 36: ...Operation Product manual 2CKA001473B8291 36 AUTO Table 7 Sequence of operating steps ...

Страница 37: ...temperature of 45 C has been set Standby mode 30 0 Menu item Standby mode is displayed only if menu item Standby times has been activated first in menu Special functions Confirm your entry with the OK button The preset temperature for Standby mode flashes 25 0 Set the desired temperature via the arrow buttons In this example a temperature of 25 C has been set Night mode 25 0 Confirm your entry wit...

Страница 38: ... Comfort Standby or Night mode There is an adjustment to the changed temperature values The AUTO time program is not executed The corresponding icons are deactivated Press the menu button to switch to the operating mode Table 8 Sequence of operating steps ...

Страница 39: ...as charged previously for several hours The flashing plug symbol see magnification shows that the mains voltage supply to the temperature controller is deactivated The time continues to run in the background but is not displayed to save energy If the temperature controller is again supplied by the mains network within a period of 10 hours the current time will be shown in the display Operation of ...

Страница 40: ...ts these can enter the device through crevices Do not spray cleaning agents directly onto the device Aggressive cleaning agents can damage the surface of the device Never use caustic agents abrasive agents or solvents Clean dirty devices with a soft dry cloth If this is insufficient the cloth can be moistened slightly with a soap solution ...

Страница 41: ...ment 10 Features of functions 10 G General information 26 I Improper use 6 Information and symbols used 5 Information on protection of the environment 9 Intended use 6 L Language 24 M Maintenance 40 Menu tree 22 Mounting 13 N Normal operation 19 Notes on the instruction manual 4 O Operating modes 18 Operation 7 17 Q Qualification of personnel 7 R Requirements for the electrician 12 RESET 24 25 Res...

Страница 42: ...tents of this document without prior notice The detailed specifications agreed upon apply for orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or extracts thereof must not be reproduced transmitted or reused by third parties without prio...

Отзывы: