PROFIBUS DP byte reference list
PROFIBUS manual
Version FELD-V2002.02
Page 19
5.5 Byte reference list
5.5.1 Mode 1 (PLC-Out)
Data from master to slave
Byte
Function
Section
Comments
0
PLC inputs Byte 1
5.1.1
1
PLC inputs Byte 2
5.1.2
Data from slave to master
Byte
Function
Section
Comments
0
PLC outputs Byte 1
5.3.1
1
PLC outputs Byte 2
5.3.2
2
PLC outputs Byte 3
5.3.3
5.5.2 Mode 2 (PLC-Out, min. general curve data)
Data from master to slave
Byte
Function
Section
Comments
0
PLC inputs Byte 1
5.1.1
1
PLC inputs Byte 2
5.1.2
Data from slave to master
Byte
Function
Section
Comments
0
PLC outputs (1st byte)
5.3.1
1
PLC outputs (2nd byte)
5.3.2
2
PLC outputs (3rd byte)
5.3.3
3
AbsMinY; X-coord. (1st byte)
5.4.1
min. general curve data:
4
AbsMinY; X-coord. (2nd byte)
5.4.1
Min. Y of whole curve
5
AbsMinY; X-coord. (3rd byte) 5.4.1
X-coordinate
6
AbsMinY; X-coord. (4th byte)
5.4.1
(32-bit float)
7
AbsMinY; Y-coord. (1st byte)
5.4.1
min. general curve data:
8
AbsMinY; Y-coord. (2nd byte)
5.4.1
Min. Y of whole curve
9
AbsMinY; Y-coord. (3rd byte) 5.4.1
Y-coordinate
10
AbsMinY; Y-coord. (4th byte)
5.4.1
(32-bit float)
11
AbsMaxY; X-coord. (1st byte)
5.4.1
min. general curve data:
12
AbsMaxY; X-coord. (2nd byte)
5.4.1
Max. Y of whole curve
13
AbsMaxY; X-coord. (3rd byte) 5.4.1
X-coordinate
14
AbsMaxY; X-coord. (4th byte)
5.4.1
(32-bit float)
continued on next page