PROFIBUS DP data protocol
PROFIBUS manual
Version FELD-V2002.02
Page 15
5.
PROFIBUS DP data protocol
5.1 Transfer from master to slave
2 bytes of PLC-In data for the DIGIFORCE
®
is always transferred from the
PROFIBUS master to the DIGIFORCE
®
. These bits have the same function
as the parallel PLC inputs to the DIGIFORCE
®
type 9310 unit.
5.1.1
PLC inputs Byte 1
PLC inputs Byte 1 (Master
Æ
Slave)
Valid
values:
START
Bit 0 LSB
TARA-Y
Bit 1
Set spare bits to '0'
TARA X
Bit 2
RESET
STATISTICS
Bit 3
SENSORTEST
Bit 4
spare
Bit 5
spare
Bit 6
spare
Bit 7 MSB
5.1.2 PLC inputs Byte 2
PLC inputs Byte 2 (Master
Æ
Slave)
Valid
values:
PROG_0
Bit 0 LSB
PROG_1
Bit 1
Set spare bits to '0'
PROG_2
Bit 2
STROBE
Bit 3
AUTO
Bit 4
spare
Bit 5
spare
Bit 6
spare
Bit 7 MSB
In all cyclical modes, 2 bytes are always transferred from master to slave.
These two bytes are used to control the device via the PROFIBUS, and have
the same meaning in all 9 modes.