See our catalog at
www.burrking.com
Contact us at
M254585opinst NEW 2009.doc - 12/30/2009
5
NOTE: The machines are adjusted at the factory for a
ceramic media load with maximum specified part load.
If lighter media (such as walnut shell) is used, or light
part loads are instilled the drive energy should be
reduced by adjusting the rotating counter weights as
previously described. Doing thus will reduce the
tendency of the machine to walk while retaining
sufficient drive energy for good processing.
These are only a starting point. The drive percentage
will be affected by the weight of your part load along
with the weight per cubic foot of media.
NOTE: Your machine may be operated with many
media types. Your machine is provided with a plugging
accessory that is to be installed when dry media is used.
This accessory is a simple plumbing part that is to be
threaded into the drain outlet of the chamber. Of
course, when performing dry processing the fluid
delivery system is turned OFF. If you desire to switch
the machine back to wet processing, remove the
plugging accessory, clean the dry media from the drain
plumbing, and connect the wet drain plumbing.
Operation of your VibraKING
The “on/off” controls for the main drive motor and the liquid pump are marked on the control panel.
During processing you will normally apply both switches to the “on” position. Leaving the liquid pump in the “off”
position inhibits the delivery of liquids and compounds.
VibraKING chambers are shipped from the factory with a re-circulating liquid supply system that includes a switch,
pump, connecting hose, metering valve, and recovery sump bucket that serves to collect the fluid output from the
chamber. If you purchased a FilterPAK 4001 with the machine the machine will be plumbed for this accessory.
In general, adjust the inlet fluid valve to “offline” about 60 degrees. Use enough fluid to maintain the media wet but not so
much as to leave fluid standing in the machine, which will dampen operation. Of course use of certain dry application
media types such as walnut shell require that the fluid be left in the OFF condition.
Reference weight adjustments:
80% Drive – Ceramic Media
70% Drive – Plastic Media
60% Drive – Dry Media
Factory Set-up on a M45 for Ceramic
Notice the 2
nd
dot on the weights. Starting on the outside
weight, align the set screw to the flat area of the shaft. Then
begin to align the weight from there making sure that the left
and right side are similar. To change to 70% drive adjust the
weights so you can see three dots.
NOTE: The drain (P/N 3599, 3599-1, 0r 3599-2) for your machine was installed at the factory, it can be removed
and replaced. Drain 3599 has 0.201 diameter holes and is installed as the standard drain at the factory. Should
the media you select require a finer drain select P/N 3599-1 with 0.125 diameter holes, or for a drain less prone to
plugging select P/N 3599-2 with 0.257 diameter holes.
Содержание 25100
Страница 17: ......