TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TE E2
Short circuit of temperature
sensor of exhaust gases
CH btm E1
Temperature sensor of lower
part of buffer tank is missing
(when in chosen scheme
with buffer tank)
CH btm E2
Short circuit of temperature
sensor of lower part of
buffer tank (when in chosen
scheme with buffer tank)
CH top E1
Temperature sensor of
upperr part of buffer tank
is missing (when in chosen
scheme with buffer tank)
CH top E2
Short circuit of temperature
sensor of upper part of
buffer tank (when in chosen
scheme with buffer tank)
When restarting the controller alarm is
deactivated.
Notify the authorized installer/
service to be performed
immediately inspection of the
boiler and heating installation.
”С”
symbol means that
the motor of automatic
cleaning system
is
activated.
The symbol
“T”
indicates that a room
thermostat
is
connected to the controller of the burner
(the boiler). In
“CH Priority”
mode the
room thermostat controls the burner by
starting and stopping it. In
“DHW Priority”
mode the room thermostat controls the
heating installation pump by starting it
when the temperature of the domestic
hot water has reached the maximum
preset temperature. In
“Parallel Pumps”
mode the room thermostat controls the
heating installation pump regardless of
the temperature of domestic hot water. In
“Summer Mode”
the room thermostat is
disabled.
Lights for operating:
-
Pump heating system
-
Pump Domestic hot water
.
10.2. User menu
10.2.1. Initial (start-up screen) „Standby“
The burner is in
standby mode.
The display shows:
Temperature in the
boiler (23 degrees),
time, and by pressing the Enter button
you can browse the quick menu (bottom
left) where the following read-only data
is displayed:
Maximum set temperature
t=85
o
C
,
temperature of domestic hot
water
where such heating circuit is
connected); exhaust outlet temperature.
Light intensity in the burner
;
Burner
status
(detected errors, if any);
Date.
Error message. If there
is an emergency in the
operation of the facility for any reason will
be displayed as an error.
Мaximum set boiler
temperature.
Current date.
Parameter
t
DHW
indicates temperature
of domestic hot water inside the water
heater.
Parameter
t
СН
indicates
the
value
of
instantaneous temperature at upper and
bottom part of the buffer tank.
This screen is active only when has been
selected the menu option for boiler
control according to buffer temperature.
Parameter
t
E
indicates
exhaust
gases