BECKETT OIL BURNER PART NOS. FOR V7 SERIES BOILERS

NOTE:  When ordering parts always give the serial and model numbers shown on the boiler and burner.  Also
           provide the name of the part(s) and part number as listed below.

Boiler Model

V72

V713

V73

V714

V74

V75

V76

V77

V78

V79

Air Tube Combination

AFG70MB

AF72YH

AF44XN

AF72YY

AF44WH

AF44RA

AF44XO

AF72WK

AFG50MD AFG50MD

Beckett's Spec No.

BCB6111

BCB6119

BCB6112

BCB6120

BCB6113

BCB6114

BCB6115

BCB6116

BCB6117

BCB6118

Air Band

3492

3492

3492

3492

3492

3492

3492

3492

3492

3492

Air Band Nut

4150

4150

4150

4150

4150

4150

4150

4150

4150

4150

Air Band Screw

4198

4198

4198

4198

4198

4198

4198

4198

4198

4198

Air Shutter

3709

3709

3709

3709

3709

3709

3709

3709

3709

3709

Air Shutter Screw

4198

4198

4198

4198

4198

4198

4198

4198

4198

4198

Blower

2999

2999

2999

2999

2999

2999

2999

2999

2999

2999

Coupling

2454

2454

2454

2454

2454

2454

2454

2454

2454

2454

Low Firing Rate Baffle

5880

5880

[1]

---

[1]

---

---

---

---

---

Bulkhead Knurled Locknut

3666

3666

3666

3666

3666

3666

3666

3666

3666

3666

Connector Tube Assembly

5636

5636

5636

5636

5636

5636

5636

5636

5636

5636

Electrode Clamp

149

149

149

149

149

149

149

149

149

149

Electrode Clamp Screw

4219

4219

4219

4219

4219

4219

4219

4219

4219

4219

Electrode Insulator Assembly

5780

5780

5780

5780

5780

5780

5780

5780

5780

5780

Spider Spacer Assembly

5503

5503

5503

5503

5503

5503

5503

5503

5503

5503

Escutcheon Plate

3493

3493

3493

3493

3493

3493

3493

3493

---

---

Adjusting Plate Assembly

---

---

---

---

---

---

---

---

5941

5941

Head

5912

360003

[4] 360004

360006

[5] 360004 [6] 360006 [7] 360012

360016

5913

5913

Head Screws

4221

4221

4221

4221

4221

4221

4221

4221

4221

4221

Flange Gasket

31498

31498

31498

31498

31498

31498

31498

31498

31498

31498

AFG Housing

5877

5877

5877

5877

5877

5877

5877

5877

5877

5877

Motor

2456

2456

2456

2456

2456

2456

2456

2456

2456

2456

Nozzle Adapter

213

213

213

213

213

213

213

213

213

213

Nozzle Line Electrode Assembly

NL72BN

NL72YH

NL44YH

NL72YY

NL44WP

NL44YB

NL44X0

NL72WK

NL50MD

NL50MD

Pump

2460

2460

2460

2460

2460

2460

2460

2460

2460

2460

Static Plate

3384

3384

[2] 3384

3384

[3] 3383P

3384

3383P

None

3383P

3383P

Ignitor

51771

51771

51771

51771

51771

51771

51771

51771

51771

51771

Ignitor Hinge Screw

4217

4217

4217

4217

4217

4217

4217

4217

4217

4217

Ignitor Holding Screw

4292

4292

4292

4292

4292

4292

4292

4292

4292

4292

Ignitor Gasket Kit

51304

51304

51304

51304

51304

51304

51304

51304

51304

51304

Wire Guard

10251

10251

10251

10251

10251

10251

10251

10251

10251

10251

Junction Box

5770

5770

5770

5770

5770

5770

5770

5770

5770

5770

Flame Detector

7006

7006

7006

7006

7006

7006

7006

7006

7006

7006

Oil Solenoid Valve

21789

21789

21789

21789

21789

21789

21789

21789

21789

21789

[1] 5880 in V73R, V73M and V74R   [2] 3912 in V73M and V73R    [3] 3384 in V74M and V74R   [4]360000 in V73R; 360003 in V73M
[5] 360003 in V74R and V74M   [6] 360003 in V75R; 360006 in V75M   [7] 360006 in V76R; 360012 in V76M

Содержание V7 SERIES

Страница 1: ...he installationofULClabeled V 7 Series Boilers As an ENERGY STAR Partner Burnham Corporation has determined that the V73WR 0 60 GPH V74WR 0 80 GPH V75WR 0 90 GPH and V76WR 1 15 GPH meet the ENERGY STA...

Страница 2: ...ASON FOR ANY OBSTRUCTIONS A CLEAN AND UNOBSTRUCTED CHIMNEY FLUE IS NECESSARY TO ALLOW NOXIOUS FUMES THAT COULD CAUSE INJURY OR LOSS OF LIFE TO VENT SAFELY AND WILL CONTRIBUTE TOWARD MAINTAINING THE BO...

Страница 3: ...Size Water Content Gallons Heat Transfer Surface Area Sq Ft Approximate Shipping Weight LB A B C Steam Boiler Water Boiler Steam Boiler V72 11 3 8 6 3 8 5 8 x 8 x 15 10 6 381 V713 16 8 3 4 6 8 x 8 x...

Страница 4: ...4 Figure 1B V73 thru V79 Water Boiler with Tankless Heater WBT Figure 1C V73 thru V79 Steam Boiler with or without Tankless Heater SBT or SB...

Страница 5: ...5 Figure 1E V713 and V714 Packaged Water Boiler with Tankless Heater WBT Figure 1D V713 and V714 Packaged Water Boiler Less Tankless Heater WB Burnham...

Страница 6: ...de at least 24 clearance from front jacket panel for servicing and removal of front tankless heater increase to 30 for A54 heater Provide at least 24 clearance from right side of boiler or top of boil...

Страница 7: ...If loose retighten mounting hardware If flue plate or sealing insulation is damaged repair or replace as needed G INSTALL AND SECURE CANOPY with cerafelt gasket and hardware provided to ensure gas ti...

Страница 8: ...ss Probe LW CO Water G aug e G lass Pre ssuretrol a nd LW CO Flo at Flush Plu g F L4 006 A Op era tin g C on trol Disre gard L81 24 C Op era tin g C on trol G 1 Bushe d to for Draincock O ptiona l Re...

Страница 9: ...Fold panel at perforation keeping insulation inward Align left side panel mounting holes with the front and rear panel holes Secure with 8 x long sheet metal screws 5 Install jacket top panel Place ja...

Страница 10: ...e slot with vertical set of bolts engage hex head of bolts and rotate burner to the left Install two remaining 5 16 x long bolts in horizontal sets of holes Level burner and fully tighten all bolts K...

Страница 11: ...eturn on water boilers 5 If CIRCULATOR not supplied with boiler is to be mounted directly to 1 boiler return tapping G use the piping arrangements outlined in steps a thru e as follows a Thread 1 x 3...

Страница 12: ...ded in trim bag See Figure on previous page Connect wiring harness from Low Water Cutoff See Figure below TS 39 126 A 5 If this boiler is used in connection with refrigeration systems the boiler must...

Страница 13: ...13 Fig 8 V73 Thru V79 Recommended Boiler Piping For Gravity Return Steam Boiler Fig 9 V72 thru V79 V713 and V714 Recommended Boiler Piping for Series Loop Forced Hot Water System TS 39 17 D TS 39 4 C...

Страница 14: ...he distribution system 5 Isolating the boiler from the system water by installing a heat exchanger F CONNECT TANKLESS HEATER PIPING AS SHOWN IN Figure 12 See Tables 3 and 3A for Tankless Heater Rating...

Страница 15: ...raft at all times to assure safe proper operation of the boiler See Figure 13 for recommended installation 1 Install a draft regulator supplied with boiler following the instructions furnished with th...

Страница 16: ...nto a container Continue to bleed for 15 seconds after oil is free of air bubbles Stop burner and close valve requires less fuel to be burned and sends less heat up the chimney A new boiler probably h...

Страница 17: ...S Figure 15 TABLE 4 SINGLE STAGE UNITS 3450 RPM TWO PIPE SYSTEMS Lift H See Fig 16 Manimum Length of Tubing H R See Figure 16 3 8 OD Tubing 3 GPH 1 2 OD Tubing 3 GPH 0 84 100 1 78 100 2 73 100 3 68 10...

Страница 18: ...be low water cutoffs will shut down the burner after a 10 15 second delay if the water level in the boiler drops too low The Hydrolevel CG 450 and the McDonnell Miller PS 804 120 low water cutoffs wil...

Страница 19: ...er cut off will shut down the burner if the water level in the boiler drops too low The control resets and restarts the burner with a call for heat a few seconds after the water is returned to its nor...

Страница 20: ...t by the thermostat energizes the L8124C control which in turn energizes the R4184D primary control to turn on the burner If burner ignites within approximately 45 seconds and the cad cell sees flame...

Страница 21: ...WITHOUT TANKLESS HEATERS set high limit dial on L8148 at 210 F This temperature may be varied to suit requirements of installation 6 On WATER BOILERS WITH TANKLESS HEATERS set operating control dial...

Страница 22: ...the ability to control air by moving the head either forward or back Loosen the adjusting plate assembly hold down screw Slide the head and plate to the required firing rate setting as shown in Figure...

Страница 23: ...service is complete be sure to fasten down the ignitor 7 FLAME FAILURE The V7 boiler controls operate the burner automatically If for unknown reasons the burner ceases to fire and the reset button on...

Страница 24: ...at cell is securely in socket Reconnect leads Reset safety switch h Close line switch If burner starts and runs beyond safety switch cut out time cell is good If not install new cell 3 WARNING Check H...

Страница 25: ...tion of mud scale etc and clean as required Examine all visible wiring for brittle or worn insulation and make sure electrical contacts are clean and that they function properly Give special attention...

Страница 26: ...manner i Remove safety relief valve using extreme care to avoid damaging it ii Add an appropriate amount of Continue this slow boiling and trickle of overflow for several hours until the water coming...

Страница 27: ...ceman to have 2 FLAME SHAPE Looking into the combustion chamber through the observation door the flame should appear straight with no sparklers rolling up toward the crown of the chamber If the flame...

Страница 28: ...N This boiler contains controls which may cause the boiler to shut down and not restart without service If damage due to frozen pipes is a possibility the heating system should not be left unattended...

Страница 29: ...ture fall R B will make and R W will break at 130 F Set low limit indicator at the minimum temperature recommended for domestic hot water supply This setting must be at least 20 F below high limit set...

Страница 30: ...s necessary to allow removal of the jacket top panel and canopy smokebox c Remove the jacket top panel d Remove the canopy being careful not to damage the ceramic fiber gasket 5 Using a 1 diameter wir...

Страница 31: ...er Illinois A Albany Fulton Montgomery B Loudoun Northampton and Indiana A Rensselaer Saratoga Prince William Counties Iowa A Schenectady Schoharie All other Counties A Kansas A Warren Washington Coun...

Страница 32: ...32 BARE BOILER ASSEMBLY...

Страница 33: ...ning Machined 71727036 1 1 1 1 1 1 1 6 5 Cast Iron Slip Nipple 7066003 1 2 3 4 5 6 7 8 7 2 Cast Iron Slip Nipple 7066001 1 4 2 6 3 4 5 6 7 8 8 Rear Target Wall Insulation 8202701 1 1 1 1 1 1 1 1 1 1 8...

Страница 34: ...34 BARE BOILER ASSEMBLY CONTINUED...

Страница 35: ...wing Door Mounting Plate 7172705 1 1 1 1 1 1 1 1 1 1 14A Burner Swing Door Mounting Plate Insulation 82027021 1 1 1 1 1 1 1 1 1 1 15 Rope Gasket Burner Mounting Plate 53 Lg 72027014 1 1 1 1 1 1 1 1 1...

Страница 36: ...36 TS 39 112 D V713 and V714 FLUSH JACKET...

Страница 37: ...de Top Panel Assembly 604270314 1 604270414 1 4 Jacket Top Panel Assembly 604270322 1 604270422 1 5 Jacket Lower Right Side Panel Assembly 604270337 1 604270437 1 6 Jacket Upper Right Side Access Pane...

Страница 38: ...38 V72 Thru V79 FLUSH JACKET TS 39 109 D...

Страница 39: ...acket Left Side Top Panel Assembly 604270241 1 604270341 1 604270441 1 604270541 1 604270641 1 604270741 1 604270841 1 604270941 1 5 Jacket Top Panel Assembly 604270221 1 604270321 1 604270421 1 60427...

Страница 40: ...40 V73 Thru V79 STEAM BOILERS TRIM AND CONTROLS...

Страница 41: ...Syphon NPT x 4 x 180 806603030 1 1 1 1 1 1 1 3D1 Bushing NPT x NPT 806600508 1 1 1 1 1 1 1 3D2 Elbow NPT 806601520 1 1 1 1 1 1 1 3D3 Nipple NPT x 2 806600003 1 1 1 1 1 1 1 3E Gage Glass Set 6 ConBraC...

Страница 42: ...42 V72 Thru V79 V713 and V714 WATER BOILERS TRIM AND CONTROLS...

Страница 43: ...1 1 1 1 1 1 1 1 3C Honeywell R4184D 1027 1001 Protectorelay 80160473 1 1 1 1 1 1 1 1 1 1 4 CIRCULATOR PIPING Packaged Boiler Only 4A Circulator Taco 007F position 2 8056007 1 1 1 1 1 1 1 1 1 1 4B Gas...

Страница 44: ...44 Beckett AFG Burner...

Страница 45: ...3 5503 5503 5503 5503 5503 5503 5503 5503 5503 Escutcheon Plate 3493 3493 3493 3493 3493 3493 3493 3493 Adjusting Plate Assembly 5941 5941 Head 5912 360003 4 360004 360006 5 360004 6 360006 7 360012 3...

Страница 46: ...46 Print word document...

Страница 47: ...47...

Отзывы: