16.

 

Points to Note Regarding the Catalytic Convertor!  

 

 

 

If  the  customer  smokes  tobacco  products,  lives  on  a  busy  road  or  is  cooking  with  a  gas 
oven/hob  at  the  time  of  testing  you  must  ensure  that  an  ambient  CO  reading  is  taken 
before lighting the fire and attempting a reading.  

 

 

Does  the  catalytic  convertor  need  replacing? 

The  catalytic  convertor  does  not  need 

replacing  unless  it  has  become  physically  broken  or  the  combustion  test  shows 
deterioration  in  performance  over  time.  To  constantly  test  the  performance  of  the 
catalytic converter, our laboratory has been running appliances eight hours per day, five 
days per week, for up to seven years. Periodically we send catalytic converters back to the 
manufacturer for testing. After the equivalent of 30 years of use, the catalytic converter is 
as  efficient  as  it  was  when  brand  new.  Burley  manages  to  achieve  this  by  designing  the 
fire to ensure that the catalytic converter is in exactly the right position for long life and 
maximum efficiency. (For other makes of fire please consult the relevant manufacturer). 
Only use replacement catalyst supplied by Burley.  

 

 

If  you  or  the  customer  detects  any  odours  from  the  fire  please  remember  that  the 
catalytic convertor is not an air filter and does not remove smells. The ceramics in the fire 
can  absorb  household  smells  and  in  turn  these  smells  get  emitted  when  the  fire  is  lit, 
especially if the fire is used in an enclosed space for a period of time. If this is the case we 
recommend  that  the  fire  is  run  on  maximum  for  at  least  5  hours  with  the  doors  and 
windows  open.  This  should  be  done  at  least  twice  a  year,  preferably  in  the  spring  and 
autumn or at any time they notice a smell.  

 

 

We do not advise the burning of wax candles within 1 metre of the fire. Wax particles can 
become  airborne  and  deposit  and  solidify  in  the  fire  causing  potential  combustion 
problems.  

 

 

The catalyst can also be affected by airborne paint smells and vapors from some plug in 
air  fresheners.  The  fire must  be  removed  or  sealed  if  you  plan  to  decorate  anywhere  in 
the house. If you can  detect smells from  the fire  carry out  the burning off  procedure as 
above.  

 
 
 

Further information regarding the catalytic convertor and Flueless fires in general can 
be found on our website 

www.burley.co.uk

  

Содержание G4240

Страница 1: ...H THE USER Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 e mail info burley co uk web www burley co uk G4240InstUser G20 31 Issue Sept08 v...

Страница 2: ...n Injector manual valve Elbow 92 300 Elbow 92 90 Injector remote Elbow 92 170 Elbow 92 85 The inlet pressure must be within 1mBar of specification with all gas appliances in the house switched on and...

Страница 3: ...tre m divide the room volume in cubic feet by 35 3 3 7 The heater must not be installed in high rise blocks of flats unless a gas supply already exists bed sitting rooms basements which are not open o...

Страница 4: ...xtra part no SPACERKIT and can stand directly against a wall Care should be taken with wall coverings as it may discolour them over time 4 3 The fire comes with a 60mm spacer fitted to the front trim...

Страница 5: ...the pull from the cavity causing heat build up on the fire surround back panel or moisture ingress from the cavity 4 12 Any under grate draught devices must be sealed off 4 13 If using the fire in a...

Страница 6: ...pushing gas pipes through walls seal the pipe ends to prevent debris entering the pipes 6 4 Drill and fit cable fixing positions in accordance with diagram or alternatively drill and fit screws throu...

Страница 7: ...rect coal is fitted in the correct place There must be a clear gap between the two sets of coals Always replace the glass after laying the coals Do not attempt to use the unit with broken damaged glas...

Страница 8: ...there is a pressure of 20mb 1mb for natural gas appliances or 37mb for propane appliances Now turn on every other gas appliance in the house and re check the pressure The pressure must still be within...

Страница 9: ...remove all debris around the pilot light The logs and backing brickwork contain refractory fibre RCF Excessive exposure to these materials may cause temporary irritation to the eyes skin and respirato...

Страница 10: ...7927 first zero the equipment and sample the entire width of the combustion product outlet Ratio of CO CO2 should be less than 0 002 within 30 minutes 20ppm CO per 1 CO2 A reading of CO in the room ce...

Страница 11: ...e made battery housing Note If the fire emits a beeping sound this is just the safety system priming itself Because the remote control uses battery power when in the stand by mode The battery will nee...

Страница 12: ...sensor into a clearer position In the event of the fire not working check both of the above points before calling an engineer 5 To ignite the fire point the handset at the fire push and hold simultane...

Страница 13: ...the test must be carried out in accordance with BS5871 Pt 4 The catalytic converter needs heat to work therefore before you start testing the fire must have been lit and burning on full for at least...

Страница 14: ...e consult the relevant manufacturer Only use replacement catalyst supplied by Burley If you or the customer detects any odours from the fire please remember that the catalytic convertor is not an air...

Страница 15: ...nstaller Tolerances It is important to take a gas rate test over a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more cr...

Страница 16: ...hin the first year as with all gas products every gas appliances must be serviced every year The appliance has not been subject to misuse accident or repaired or fitted by anyone other than a CORGI fi...